Konica Minolta LU-204 Скачать руководство пользователя страница 7

E-7

27. Slide the large capacity unit and remove it from 

the main unit.

28. Remove the lower rear right cover of the main 

unit and cut the knockout off (two screws).

29. Connect the two large capacity unit harness con-

nectors into the relay harness connectors that 
come from the main unit.

30. Connect the connectors and connect the ground 

wire with the screw furnished with the unit then 
insert the cord clamp (one screw).

31. Reinstall the lower rear right cover of the main 

unit that has been removed in step 28 and put 
the cable into the groove (two screws).

32. Slide the large capacity unit towards the main 

unit and lock it.

A0TJIXC034DA

A0TJIXC022DA

A0TJIXC023DA

A0TJIXC035DA

Содержание LU-204

Страница 1: ...ss approx 25 kg 55 lb I Accessory parts No Name Shape Q ty 1 Rail 1 2 Mounting bracket A 1 3 Mounting bracket B 1 4 Mounting bracket C 2 5 Screw 4 x 8 mm 11 6 Label 1 set A0TJIXC027DA A03NIXC002DA A03...

Страница 2: ...e two places two screws for each bracket 5 Install the mounting bracket A onto the rail Both parts are furnished with the unit 6 Fit the tab of the mounting bracket A onto the groove on the ceiling of...

Страница 3: ...mm is ensured between the main unit and the large capacity unit Note If there is no gap between the main unit and the large capacity unit the large capacity unit has been placed too close to the main...

Страница 4: ...screws each for front and rear and the left side two screws each for front and rear of the large capacity unit Then remove the front cover 15 Remove the plate from the rear side of the large capacity...

Страница 5: ...front and rear counterclockwise the overall length of the right adjustment roller legs is short ened and therefore the right side of the unit is lowered Until the gap 3 0mm 2 0mm is ensured between th...

Страница 6: ...or front and rear of the large capacity unit Note Before reinstalling the covers position the right adjustment rollers front and rear as shown in the illustration 24 Reinstall the plate that has been...

Страница 7: ...harness connectors that come from the main unit 30 Connect the connectors and connect the ground wire with the screw furnished with the unit then insert the cord clamp one screw 31 Reinstall the lowe...

Страница 8: ...paper to be loaded six screws 4 Raise the paper feed roller 5 Load a stack of paper and align it to the left side of the large capacity unit Note Ensure that a stack of paper does not go past the upp...

Страница 9: ...nt will be produced 5 Measure width A from the edge of the paper to the pattern printed on the test print and check that it falls within the specified range Specifications 3 0 mm 1 0 mm Adjusting the...

Страница 10: ...T and then press the Start key A test print will then be produced 3 Measure width A of the test pattern on the back side of the test print produced and check that it falls within the specified range S...