Chapter 1 Before Use
1-9
Name of part
Function
Exit Cover
Can remove the mis-fed media around Fuser section.
Interface Connector for
Controller PC (CH-B)
Connect the cable here, which comes from a controller PC.
D-Sub Connector 36 pins, 3.3Vdc maximum (large)
Cable KATSURAGAWA ELECTRIC P/N: Z156400090
Folder Port
Connect this port and a finishing device (Folder, etc) with a cable.
12Vdc maximum See the document of the folder/controller for
communication with the folder.
S. DOWN Port
Connect the Shutdown Signal Cable here.
KIP 9900 will send a shutdown signal to the controller through this
cable. 12Vdc maximum
Cable KATSURAGAWA ELECTRIC P/N :Z156400380
Diag Port (USB)
For Service personnel only
Connector Type B, 5Vdc maximum
VGA Port
Connect the VGA cable here, which comes from a controller VGA port
by UL-Listed cable for Touch screen LCD. 5Vdc maximum
USB Port
Connect the USB cable here, which comes from a controller USB Key
Connector Type B for Touch screen LCD. 5Vdc maximum
Cable KATSURAGAWA ELECTRIC P/N : Z156460020
Top Rear Cover
Can access the Dehumidify Heater Switch.
Outlet for Controller PC
In case you place a controller unit outside of the KIP 9900, it is possible
to supply AC power from the KIP 9900 to the controller unit if you
connect the power cord to this outlet. (220 - 240V, 3A maximum)
Dehumidify Heater
Switch
Turn on the Dehumidify Heater pressing “H” side of this switch to
dehumidify the printing media.
Press “L” side to turn it off.
(continued on the next page)
NOTE
Specification for Power Cord used in North America
Use the following type of Power Cord for a controller PC.
1) Rating
minimum 250VAC 7A
2) Plug Type
IEC60320: C13
3) Socket Type
IEC60320: C14
4) Cord
H05VV-F 3G-0.75mm, SVT3x18AWG
5) UL-Listed
NOTE
The above specifications are subject to change without notice.