E-10
(20) Verify items
➀
and
➁
below.
➀
The plate spring of the plate installed in step
(14) is contacted with the main body.
➁
When the lever that was pulled out in step (18)
is pushed back, the finisher’s screw hole is
within the range of lever’s mounting hole.
Note:
If there are any problems after verification, con-
duct the following steps a) to h).
a) Disconnect the connector, and remove the fin-
isher from the main body.
b) Remove the cover from the caster of the fin-
isher. (Two screws)
c) Remove the rear cover from the finisher. (Eight
screws)
Screw
hole
Mounting hole
on the lever
➁
➀
< OK >
Contacted
Not contacted
< NG >
Plate spring