E-4

<Installations to models 367/287/227>

(1) Turn OFF the power switch and unplug the 

power cord from the power outlet.

(2) Connect the supplied harness to the local inter-

face board unit and route the harness inside the 
edge cover.

Note:

    • Insert the black connector into the local inter-

face board unit connector.

    • Route the harness so that the cable tie is 

located at the position shown in the illustration.

(3) Install the three supplied wire saddles to the local 

interface board unit.

Note:

Install the wire saddles so that the lock faces out-
ward.

(4)
<When the optional Keypad KP-101 is mounted>

Remove the two screws and remove the cover 
on the back side of the keypad. Disconnect the 
connector and remove the keypad.

<When the optional Keypad KP-101 is not 
mounted>

Remove the cover from the main body as shown 
in the illustration. (Two screws)

(5) Open the front door of the main body.

Cable tie