13
Connect the instrument to a PC with the supplied USB cable IF-A21 (3 m).
Memo
• To connect the instrument with a PC, it is recommended that you use software that enables connection
and operation of the instrument (such as the optional Color Management Software SpectraMagic™ NX).
• The USB communication port of the instrument conforms to USB 1.1.
○
To connect the instrument to a PC, you need to install the USB driver dedicated to the CM-3600A. Install
the USB driver supplied with the software that enables connection and operation of the instrument.
○
The instrument is not designed to be powered via the USB cable. You need to connect the AC adapter.
○
Make sure that the USB connector plug is oriented correctly and connected securely.
○
When connecting/disconnecting the USB cable, be sure to hold the connector plug.
Do not pull on or forcibly bend the cable. Otherwise, wire breakage may result.
○
Make sure that the cable has sufficient length. Putting tension on the
cable may cause connection failure or wire breakage.
○
To connect the USB cable connector, check the shape of the receptacle
(connection terminal) and insert the connector fully until it is secured.
Connecting a Personal Computer
In general, a USB cable can be connected/disconnected while the instrument is turned ON; however,
you need to turn OFF the instrument in the procedure below. See P. 14 for how to connect the AC adapter
and P. 15 for how to switch the power on and off.
1.
Turn OFF the instrument (Press the
“
” side of the Power switch.).
2.
Connect the B connector of the USB
cable to the USB connection terminal
(B type) of the instrument.
○
Fully insert the connector and
ensure secure connection.
3.
Connect the A connector of the USB
cable to the USB port of the PC.
4.
Connect the AC adapter and turn ON the
instrument (Press the “ I ” side of the Power switch.).
○
When you are prompted to install the USB
driver, specify the USB driver included
with the software or the white calibration
data CD and complete the installation.
○
When using the optional Color Management
Software SpectraMagic™ NX, refer to the
SpectraMagic™ NX Installation Guide.
○
After installation of the USB driver has
finished, switch the instrument off for a few
seconds and then switch it back on.
Содержание CM-3600A
Страница 1: ...SPECTROPHOTOMETER CM 3600A INSTRUCTION MANUAL Before using this instrument please read this manual...
Страница 9: ...7 Using the CM 3600A...
Страница 30: ...28...
Страница 31: ...29 Explanations...
Страница 36: ...34 Dimensions 29 5 15 6 30 244 2 115 6 23 4 28 7 87 178 3 50 2 376 6 20 11 205 6 225 6 mm...
Страница 38: ...36 MEMO...
Страница 40: ...9222 A3UJ 12 BHEFDK 2011 2017 KONICA MINOLTA INC...