16. IMAGE QUALITY PROBLEM
241
bizhub C35
TROUBLESHOOTING
16.2.18
Printer monocolor: foggy background
A. Typical faulty images
B. Troubleshooting procedure
A02EF4C510DA
ABCD
ABCD
ABCD
ABCD
ABCD
Step
Section
Check item
Result
Action
1
IDC sensor
The surface of the IDC sensor is
dirty.
YES
Clean.
2
Imaging unit
Dirty on the outside.
YES
Clean.
3
PH unit
The surface of the PH window is
dirty.
YES
Clean with cleaning jig.
4
Printer control
board (PRCB)
Check the connection of connectors,
harness, and flat cables between
PRCB and PH unit, and correct if
necessary.
NO
Change printer control board.
5
The problem has been eliminated
through the checks of steps up to 4.
NO
Change imaging unit.
→
Change PH unit.
→
Change high voltage unit.
Содержание bizhub C35
Страница 1: ...DRAFT SERVICE MANUAL 2010 02 2010 02 Ver 1 0 Ver 1 0 FIELD SERVICE ...
Страница 3: ...DRAFT ii Blank Page ...
Страница 28: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Main body ...
Страница 135: ...DRAFT 7 OTHER MAINTENANCE ITEM Field Service Ver 1 0 Feb 2010 96 bizhub C35 MAINTENANCE Blank Page ...
Страница 227: ...DRAFT 11 FAX PROTOCOLS Field Service Ver 1 0 Feb 2010 188 ADJUSTMENT SETTING Blank Page ...
Страница 301: ...DRAFT 17 IC protector Field Service Ver 1 0 Feb 2010 262 Blank Page ...
Страница 314: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Lower Feeder Unit PF P08 ...
Страница 317: ...DRAFT Lower Feeder Unit OUTLINE MAINTENANCE Field Service Ver 1 0 Feb 2010 ii Blank Page ...
Страница 319: ...DRAFT 1 PRODUCT SPECIFICATIONS Field Service Ver 1 0 Feb 2010 2 Lower Feeder Unit OUTLINE Blank Page ...