DRAFT
14. MALFUNCTION CODE
Field Service
V
er. 1.0 Feb. 2010
216
14.4.31
6791: Register setting error
Relevant electrical parts
MFP board (MFPB)
Step
Action
WIRING DIAGRAM
Control signal
Location (electri-
cal component)
1
Reboot the main body.
-
-
2
Check the connector CN102, CN103 on
MFPB for proper connection and correct as
necessary.
-
-
3
Change MFPB.
-
-