Theory of Operation Ver. 1.0 Apr. 2005
11. Developing
33
bizhub 162 bizhub 210
Composition/Operation
11.3 ATDC Sensor
• The ATDC Sensor detects the toner-to-carrier ratio (T/C) of the developer in the Devel-
oper Mixing Chamber.
11.4 ATDC Sensor Automatic Adjustment
• The reference value for the ATDC Sensor is automatically adjusted as detailed below
using the ATDC Sensor Automatic Adjustment mode.
2nd Toner Conveying Roller
ATDC Sensor
4021M019AA
3rd Toner Conveying Roller
Developing Roller
1st Toner Conveying Roller
With the copier set in the ATDC Sensor Automatic Adjustment mode, press the Start key.
The developer is mixed.
The ATDC Sensor converts the reference T/C (14 %) to a corresponding voltage
value and outputs it.
Does the output voltage fall within the range from 2.28 to 2.36 V?
YES
NO
The voltage input to the ATDC Sensor
from the Master Board at this time is fixed
as the reference voltage.
The voltage input to the ATDC Sensor from
the Master Board is varied.
2.37 V or more: Decrease the voltage.
2.29 V or less: Increase the voltage.
bizhub_162_210_TO.book 33 ページ 2005年4月18日 月曜日 午後1時27分
Содержание BIZHUB 162
Страница 1: ...SERVICE MANUAL 2005 04 2005 04 Ver 1 0 Ver 1 0 THEORY OF OPERATION...
Страница 19: ...SAFETY AND IMPORTANT WARNING ITEMS S 18...
Страница 20: ...SERVICE MANUAL 2005 04 Ver 1 0 Main Unit THEORY OF OPERATION...
Страница 21: ......
Страница 23: ......
Страница 27: ...bizhub 162 bizhub 210 Outline Composition Operation Theory of Operation Ver 1 0 Apr 2005 iv Blank page...
Страница 35: ...4 Paper path Theory of Operation Ver 1 0 Apr 2005 8 bizhub 162 bizhub 210 Outline 4 Paper path 4034G503BA...
Страница 89: ...22 Others Theory of Operation Ver 1 0 Apr 2005 62 bizhub 162 bizhub 210 Composition Operation Blank page...