18. Fusing unit section
Theory of Operation Ver. 1.0 Apr. 2005
54
bizhub 162 bizhub 210
Composition/Operation
18.5 Fusing Temperature Control (for bizhub 162)
• The Fusing Roller Heater Lamp is turned ON and OFF to keep a set temperature on the
surface of the Fusing Roller.
• The Fusing Roller surface temperature is detected by using a thermistor that translates
the temperature to a corresponding electrical signal.
• If the Fusing Roller temperature becomes excessively high, the Fusing Roller Heater
Lamp is shut down.
Machine Condition or Paper Type
Mode 1
Mode 2
Mode 3
Standby
180 °C
180 °C
→
170 °C
170 °C
Plain paper (width: 250 mm or more;
length: less than 360 mm)
190 °C
190 °C
→
170 °C
170 °C
Plain paper (width: less than 250 mm)
180°C
180 °C
→
165 °C
165 °C
Thick paper (width: 250 mm or more)
210 °C
210 °C
→
190 °C
190 °C
Thick paper (width: less than 250 mm)
200 °C
200 °C
→
190 °C
190 °C
OHP film (width: 250 mm or more)
180 °C
180 °C
→
165 °C
165 °C
OHP film (width: less than 250 mm)
155 °C
155 °C
155 °C
<Temperature Control in Standby State>
Warm-up completed
4034M541CA
bizhub_162_210_TO.book 54 ページ 2005年4月18日 月曜日 午後1時27分
Содержание BIZHUB 162
Страница 1: ...SERVICE MANUAL 2005 04 2005 04 Ver 1 0 Ver 1 0 THEORY OF OPERATION...
Страница 19: ...SAFETY AND IMPORTANT WARNING ITEMS S 18...
Страница 20: ...SERVICE MANUAL 2005 04 Ver 1 0 Main Unit THEORY OF OPERATION...
Страница 21: ......
Страница 23: ......
Страница 27: ...bizhub 162 bizhub 210 Outline Composition Operation Theory of Operation Ver 1 0 Apr 2005 iv Blank page...
Страница 35: ...4 Paper path Theory of Operation Ver 1 0 Apr 2005 8 bizhub 162 bizhub 210 Outline 4 Paper path 4034G503BA...
Страница 89: ...22 Others Theory of Operation Ver 1 0 Apr 2005 62 bizhub 162 bizhub 210 Composition Operation Blank page...