Security Function Ver. 1.02 Mar. 2016
10. Firmware rewriting
39
6.
Control panel shows F/W items to be updated, and select the particular type of F/W to
be updated. (Select [YES].)
NOTE
• Unless one of the keys on the control panel is touched, firmware is automatically
updated after 30 seconds when the main power switch is turned on.
• When the BootRom file is in the firmware data, [BootRom] key is displayed. Touch-
ing the key updates data.
• If either or both of the
S
CB file and power sub CPU file are contained within the
firmware data, the [Other FW Update] key displays. Press the key to update.
• When more than one firmware are stored in step 1, touching [FW Data
S
elect]
enables selection. (Data of other models cannot be selected.)
(At this time, the data marked with an asterisk on the upper-left side of the data
selection screen is the firmware data in the "FW0001" folder in the U
S
B memory
device.)
7.
Touch the [Language Select].
F/W to be updated
Appropriate board
Remark
MFP CONTROLLER
eMMC board (eMMC)
SCANNER/PRINTER
MFP board (MFPB)
ADF (DF-M)
DF control board (DFCB)
Only when DF-628 is mounted
FAX BOARD CONTROLLER1 Fax board/1 (FAXB/1)
Only when FK-513 is mounted
FINISHER
FS control board (FSCB)
Only when FS-533/FS-534 is
mounted
SD
SD drive board (SDDB)
Only when FS-534SD is mounted
A7AH
S