4
clutches can be adjusted, see section "Service and
maintenance".
The switch at the CPU control in the column can be dis-
connected in the event of service or repair.
Warning signs:
Warning signs with symbols without text are found on
the CVL. The meaning of the symbols is explained be-
low. If a warning label gets damaged, and is no longer
legible, it must be replaced. New labels are available in
the spare parts list.
Read the user manual carefully and
observe the warning texts in the
user manual and on the CVL.
Piping must not be removed while
the CVL is in operation. Wait until
compressed air and electricity has
been disconnected.
The CVL is equipped with a yellow mark around the
compressed air supply on the back console, as this
connection acts as an emergency stop.
Warning notes:
Avoid accidents by always following the safety instruc-
tions given in the user manual and on the safety signs
located on the CPU system.
The CPU may only be activated if the area around the
system is secured against access by uninstructed per-
sons.
The mounting of the unit must be as prescribed (see
section "Installation"), if not, stability is reduced, and
wear increased.
Ensure that all guards are intact and properly secured
during operation.
Always disconnect electricity and compressed air sup-
ply to the CPU/ CVL system before making any repairs,
maintenance or removal of blocked components. In
case the blockage is removed while air supply or elec-
tricity is connected, the cylinders can move, causing
serious injury.
Never put your hand into the unit´s inlet or outlet during
operation.
Make sure the service technician / operator has secure
access to repair and maintenance of the CVL. The
working area around the unit should be clear and trip
free when carrying out maintenance.
Make sure that there is adequate lighting when working
on the CVL unit.
In case of abnormal vibrations or noise, stop the unit
immediately and examine the cause. In case of doubt,
skilled assistance must be called in for repair and main-
tenance.
Do not operate the CPU without a container below the
telescopic pipe.
To avoid any personal contact with the moving valves,
pipes of minimum 850 mm length, (maximum Ø 200
mm) must be installed onto the inlet and outlet connec-
tions. These pipes must be installed with bolt clamps,
where tools are necessary for dismantling.
In case it is not possible to use minimum 850 mm
pipes, it must be ensured, that there within minimum
850 mm from the inlet and outlet, in all connections,
are used bolt clamps, where tools are necessary for
dismantling.
The reason for this is, that according to EU-directive
2006/42/EC (Machinery Directive), it is not allowed for
any unauthorized personnel to gain access to moving
/ dangerous parts. In case quick couplings are used,
unautorized personnel could dismantle the piping, and
gain access to moving parts.
The suction head of the Component Pickup Unit sys-
tem is equipped with slip clutches in both horizontal
directions of movement to prevent clamping between
the telescopic pipe / container and the column. These
Содержание CPU
Страница 96: ...96 KCP 100R 2 meter pipe OBS Pickled Gebeizt Décapée Wytrawiane Bejdses ...
Страница 97: ...97 ...
Страница 99: ...99 ...
Страница 100: ...100 ...
Страница 101: ...101 ...
Страница 102: ...102 ...
Страница 103: ...103 ...
Страница 104: ...104 ...
Страница 106: ...106 ...
Страница 107: ...107 ...