Simrad Hydraulic Linear Drive
10
20220109E
2.4
Comparison chart for HLD MK2 versions
MODEL MOTOR
VOLTS
AUTOPILOT
COMPUTER/
JUNCTION
UNIT
MAX
STROKE
mm (in.)
PEAK
THRUST
kg (lb.)
MAX
RUDDER
TORQUE
Nm
(lb.in.)
HARD-
OVER
TIME
sec.
(30% load)
PWR.
CON-
SUMP.
TILLER
ARM
mm
(in.)
HLD350
HLD350S
12V AC10,
J3000X
200 (7,9)
350
(770)
610
(5400)
12 3,5-10
A
175
(6,9)
HLD2000L
HLD2000LS
12V AC20,
J300X
340 (13,4)
500
(1100)
1460
(12850)
12 5-16
A
298
(11,7)
HLD2000D 24V AC20,
J300X
200 (7,9)
1050
(2310)
1800
(15900)
9 5-16
A
175
(6,9)
HLD2000LD 24V
AC20,
J300X
340 (13,4)
1050
(2310)
3180
(28000)
15 5-16
A
298
(11,7)
Steering
gear
interface:
Connects
to
quadrant
or
tiller.
1.
The autopilot computer/junction unit steps down the motor voltage
when operating from 24V or 32V mains.
2.
The specified computer/junction unit is necessary to achieve max
drive unit capacity.
3.
Recommended operational thrust or torque is 70% of listed value.
4.
Typical average power consumption is 40% of listed maximum
value.
Rortilkobling: Kobles til kvadrant eller rorkult.
1.
Autopilotcomputeren/koblingsenheten regulerer ned
motorspenningen ved 24V eller 32V nettspenning.
2.
Spesifisert computer/koblingsenhet er nødvendig for å oppnå
maksimal kapasitet fra drivenhet.
3.
Anbefalt skyvkraft eller moment ved drift er 70% av oppgitt verdi.
4.
Gjennomsnittlig effektforbruk er typisk 40% av oppgitt
maksimumsverdi.