Kongsberg Simrad GI51 Скачать руководство пользователя страница 26

Sales and service worldwide 

01.03.04 

 

UNITED ARAB 
EMIRATES 

Emphor FXCO 
P. O. Box 6488  
Dubai 
Tel.: +971 4 324 7500 
Fax: +971 4 324 7503 

LEBANON 

Selcom Marine Sarl 
P. O. Box 55541 
Dekwaneh Main Street 
Beirut 
Tel.: +961 149 1489 
Fax: +961 149 5325 

IRAN 

Darya Negar Co. 
Office 2, 1

st

 Floor,  

Bldg. No. 64 
Fatemi Square 
Teheran 
Tel.: +98 21 896 7872 
Fax: +98 21 896 6658 
 

PACIFIC 

AUSTRALIA 

Quin Marine Pty. Ltd. 
89 St Vincent Street 
Port Adelaide, SA 5015 
Tel.: +61 88 447 1277 
Fax: +61 88 341 0567 

NEW ZEALAND 

Advance Trident Ltd. 
P.O. Box 4174 
Kingsland 
Auckland 
Tel.: +64 9 845 5347 
Fax: +64 9 845 5348 
www.advancetrident.com 
 

ASIA 

SINGAPORE 

Jason Electronics Pte Ltd. 
Blk 194 Pandan Loop #06-
05 
Pantech Industrial Complex 
Singapore 128383 
Tel.: +65 6  872 0211 
Fax:  +65 6 872 1800 

CHINA & HONG KONG 

CITE Limited 
Rm C-E, 16/F, Yan’s 
Tower,  
 26-27 Wong Chuk Hang 
Road , Aberdeen 
Tel.: +852 2 552 0178 
Fax: +852 2 873 0679 
 

INDIA 

Norinco Pvt Ltd. 
Karshaka Road 
Cochin 682016 
Tel.: +91 484 2323 675 
Fax: +91 484 2323 694 

INDONESIA 

PT Sarana Teknologi 
Samudera 
Wisma Dharmala Sakti  
Annexe Building 7

th

 Floor 

JL. Jenderal Sudirman 
Kav.32 
Jakarta 10220 
Tel.: +62 21 570 61 28 
Fax: +62 21 570 72 21 

SOUTH KOREA 

Lucky Susan Co. Ltd. 
K.P.O. Box 1666, Seoul 
Taesung B/D. #508 
60-17, Taepyong-Ro 1-Ka 
Chung-Ku, Seoul 
Tel.: +82 2 736 4328 
Fax: +82 2 739 5689 
 
Turn-On Electronics Co. 
7

th

 fl., Dong-A Ilbo Bldg. 

53-11, 4-KA,  
Choongang-Dong 
Choong-Ku, Pusan 
Tel.: +82 51 462 3930 
Fax: +82 51 462 3089 

JAPAN 

Nippon Kaiyo  Co, Ltd. 
9-2 Sakae-Cho  
Kita-Ku 
Tokyo 114-0005 
Tel.:  +81 3 3913 2337 
Fax: +81 3 3913 3479 
 
Shipmate Japan Co. Ltd. 2-
5-4 Fukuura 
Kanazawa-ku 
Yokohama 236-0004 
Tel.: +81 45 788 2731 
Fax: +81 45 788 2732 

TAIWAN 

Dragon & Elephant 
Enterprise Co. Ltd. 
12F-4, No. 251 
Min Chuan 1

st

 Road 

Kaohsiung, Taiwan ROC 
Tel.: +886 722 72887 
Fax: +886 722 72910 
 

AMERICAS 

CANADA 

Simrad Canada Ltd. 
P.O. Box 397 
112 Lincoln Street 
Lunenburg, Nova Scotia 
Canada B0J 2C0 
Tel.: +1 902 640 3300 
Fax: +1 902 640 3070 
www.simrad.com 

USA 

Simrad Inc. 
19210 33

rd

 Avenue West 

Suite A 
Lynnwood WA 98036 
Tel.: +1 425 778 8821 
Fax: +1 425 771 7211 
www.simrad.com 
 
Simrad Inc. 
1500 NW 1

st

 Street 

Suite 1-E 
Dania, FL 33004 
Tel.: +1 954 922 7700 
Fax: +1 954 922 0707 
www.simrad.com 

ARGENTINA 

R.C. International 
Av. Corrientes 2958 11

th

 38 

1193 Buenos Aires 
Tel.: +54 11 4862 
5774/4865 7621 
Fax: +54 11 4862 5774 

BRAZIL 

Demo Offshore Ltda 
Av. Marechal Camara 160 
Sala 614,  
Centro Rio de Janeiro 
RJ-20020-080 
Tel.: +55 21 2524 5171 
Fax: +55 21 2532 0254 

CHILE 

Simrad S.A. 
Casilla 19012, Correo 19 
Vitacura 
Santiago 
Tel.: +56 2 207 3059 
Fax: +56 2 207 2695 

PERU 

Simrad Peru S.A. 
Calle Los Topacios 266-268 
Urb. San Antonio 
Bellavista – Callao 
Tel.: +51 1 453 7477 
Fax: +51 1 453 7325 

URUGUAY 

Electromaritima Uruguaya 
Ltda. 
Guatemala 1260 
11800 Montevideo 
Tel.: +59 8 2 924 7139 
Fax: +59 8 2 924 7138 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The above companies 

represent only main 

importers. Each country 

is in addition served by 

a network of local 

service outlets. 
Some importers 

represent only specific 

market segments 

according to the 

following codes:  

Professional: 
Coastal and Fishery market 
Recreational: 
Leisure market 

 

 

 

www.simrad.com

 

Busse-Yachtshop.de     [email protected]

Содержание Simrad GI51

Страница 1: ...INSTALLATION MANUAL Simrad GI51 Gyro Interface Busse Yachtshop de info busse yachtshop de ...

Страница 2: ...rsonnel The user must be familiar with the contents of the appropriate manuals before attempting to operate or work on the equipment Simrad AS disclaims any responsibility for damage or injury caused by improper installation use or maintenance of the equipment Copyright 2004 Simrad AS The information contained within this document remains the sole property of Simrad AS No part of this document may...

Страница 3: ...INSTALLATION MANUAL 20221594 B i Installation Manual GI51 Gyro Interface This manual is to be used when installing the Simrad GI51 Gyro Interface Busse Yachtshop de info busse yachtshop de ...

Страница 4: ... Updated to include new functions Corrections updates added to other pages To assist us in making improvements to this manual we would welcome comments and constructive criticism Please send all such in writing to Simrad Egersund AS Nyåskaien P O Box 55 N 4379 Egersund Norway or by e mail to simrad documentation simrad com Busse Yachtshop de info busse yachtshop de ...

Страница 5: ...nge test 10 2 8 S9 Steering lever 11 3 GI51 PCB 12 3 1 Component location 12 3 2 Terminal description 13 TB1 Power 13 TB2 Sin Cos Out 13 TB3 Synchro In 13 TB4 NFU 13 TB5 Step Out 13 TB6 Step In 14 TB7 and TB8 NMEA 14 TB9 RGC proprietary 14 TB10 LOG 14 TB11 Radar 14 TB12 Selector 15 4 PENDULUM FUNCTION KEY OPTION 16 5 TROUBLE SHOOTING 17 5 1 LED indicators 18 6 SPARE PARTS 19 7 TECHNICAL SPECIFICAT...

Страница 6: ...Simrad GI51 Gyro Interface iv 20221594 B 7 3 Interface 21 Input 21 Output 21 Other serial output input 22 Busse Yachtshop de info busse yachtshop de ...

Страница 7: ...installation The GI51 should be mounted with regard to the environmental protection and temperature range of the unit and should not be installed in area exposed for heavy vibrations Make allowances for working area around the unit when routing or removing the cables Fasten the GI51 to the bulkhead Refer mechanical drawing page 20 2 2 Cabling All cable conductors are terminated in screw terminals ...

Страница 8: ...OS PWR SEL 2 SEL 3 SEL 4 SEL 1 12V CLK L CLK H DATA L DATA H PULSE 12V RX RX TX TX RX RX COM STEP 3 STEP 2 STEP 1 STEP 3 STEP 1 STEP 2 COM ENABLE PORT STBD 12V S3 S2 S1 R2 R1 COS SIN APGND V 2 AP TB12 TB11 TB10 TB9 TB8 TB7 TB6 TB5 TB4 TB3 TB2 TB1 ROBNET CONNECTORS J2 J1 GI51 PCB Busse Yachtshop de info busse yachtshop de ...

Страница 9: ... and Robnet speed output from the pulse log input If set to ON speed will be taken from the longitudinal water speed field of VBW 1 priority or VHW 2 priority of the NMEA input SW2 2 is used to determine the internal gain for high voltage 50 100V ref L L or low voltage 26V ref 11 8V L L synchros OFF sets the gain for high voltage level others ON sets the gain for low voltage 26V 11 8 V L L All swi...

Страница 10: ...This can be done either by a proprietary NMEA data ref page 22 or by an external switch connected between the SEL 3 and 12V 12V SEL 1 SEL 3 SEL 2 SEL 4 SELECTOR TB12 The switch must be a potentional free pulse type When pressing and holding the switch the heading will increase or decrease depending of last direction control The heading will increase in a slow rate for the first 2 degrees but chang...

Страница 11: ...ynchro is NOT standard but optional See autopilot manual for more info When compasses are connected to GI51 as stand alone and calibration may become difficult or impractical due to vessel size port condition etc a separate dip switch SW2 2 function is included to avoid the calibration See Dip switch settings page 7 Note For a 1 1 synchro minor errors may be present therefore a calibration when th...

Страница 12: ...need to be changed Use one of the alternatives listed below If the compass can be slewed heading changed use the procedure in Alternative 1 If it is not possible to slew the compass Alternative 2 should be used Alternative 1 Disconnect S1 S2 S3 from GI51 TB3 Slew the master compass to 000 Use a multimeter and measure the AC voltage 0 90V range between S1 S2 S3 on the disconnected wires Locate the ...

Страница 13: ...y The S9 is designed to be mounted in weather exposed locations If it is installed in such location it is recommended to insure that the cable entry glands are properly tightened In addition silicone sealant should be added around cable to ensure water protection As the mode selection by the Enable signal is based on a pulse it is recommended that only one S9 lever is used This because the mode se...

Страница 14: ... Pulse NMEA RGC TX RX RX TX RX RX Com CPU RUNNING OK POWER Port STEP OUT Step 3 Step 1 Step 2 Com Step 1 Step 2 Enable NFU SYNCHRO 12V Stbd S3 S2 S1 R2 R1 PWR SIN COS V 2 Cos APGND Sin AP J1 J2 CONNECTORS SW2 SW1 PLUG FUNCTION KEY PROGRAM FAULT SYNCHRO SPEED LOG PULSE CLK RADAR RGC RX RX NMEA TX NMEA IN STEP STEP OUT LED F1 Busse Yachtshop de info busse yachtshop de ...

Страница 15: ...o In R2 SYNCHRO S2 S3 S1 R1 Used for connecting gyro compasses with synchro output Refer Dip switch settings page 7 for signal specification TB4 NFU Enable Port Stbd 12V NFU Used for connecting a remote Non Follow Up lever Rudder command or course change will be sent to the autopilot via Robnet Simrad S9 lever also enables remote auto NFU mode switching TB5 Step Out Step 2 Step 3 Step 1 STEP OUT C...

Страница 16: ...e steering compass and speed from log in the GI51 is available on TX and TX TB9 RGC proprietary RX RX RGC Used for reading serial data 9600 baud from gyro compass RGC11 RGC12 TB10 LOG Pulse 12V LOG Used for connecting speed log with 200p NM Refer Dip switch settings page 7 TB11 Radar Data L RADAR Clk L Clk H Data H Data and Clock output signal to Radar Simrad or Furuno format is selected via Robne...

Страница 17: ... heading will increase or decrease depending of last direction control The heading will increase in a slow rate for the first 3 degrees but change to high rate for as long as the switch is depressed By making a quick double press and keep the last press the direction is reversed and started with low rate Single presses on the switch changes the heading by one tenth of a degree Pendulum ferry featu...

Страница 18: ... GI51 pcb Refer page 15 A LED is visible through the whole on the key The LED has the following indication No light true heading output Intermediate flashing heading is changed 180 Use the following procedure to install the pendulum key 1 Remove power from the GI51 unit 2 Open the unit and locate P1 on the pcb Refer Component location page 12 Pendulum function key P1 3 Carefully insert the pendulu...

Страница 19: ...ro Stop clk data output Transmit invalid flag and empty heading field in NMEA output 2 If all output indicators operate ok check cabling for missing output signal 3 If output indicators show missing or invalid input all 3 LEDs for step out is lit etc check LED s for selected input compass 4 If LED s for selected input compass operate ok check compass status 5 If LED s for selected input compass in...

Страница 20: ...correct status for power and input output signals For location of the LEDs refer to Component location page 12 LED NO COLOUR INDICATION D1 Green CPU running indicator Flashes with apr 1Hz when the processor is running D103 Green Power polarity indication Green light when polarity is correct D400 D401 D401 Green Step out indicators Flashes with Step Out signal D603 Green NMEA In indicator Flashes w...

Страница 21: ...INSTALLATION MANUAL 20221594 B 19 6 SPARE PARTS PART NO DESCRIPTION 20213773 GI51 Gyro Interface 20213278 GI51 board 20213815 GI51 Pendulum key Busse Yachtshop de info busse yachtshop de ...

Страница 22: ... Protection IP44 Safe distance to magnetic compass 0 2 m 0 7 ft Temperature range Operation 25 to 55 C 13 to 130 F Storage 30 to 80 C 22 to 176 F Cable inlets Rubber glands for cable diameter 10 14mm Mounting Bulkhead mount 7 2 Supply Supply voltage 12 24 or 32V DC 30 10 or Robnet 26 42V DC Power consumption 2 4 W Load Maximum 20 mA Busse Yachtshop de info busse yachtshop de ...

Страница 23: ...NFU with mode sel S9 Pot free contacts Robnet Heading steering comp T or M Radar interf type Selector Pendulum function Offset adjustment Output Analog sin cos AP45 0 5V DC Step 6 step max rate 20 sec 24V DC 20mA Simrad Anritsu Furuno clk data for 2 radars 0 5V 40Hz 20mA NMEA183 Heading HEHDT HEHDG 10Hz Speed and heading HEVHW PSIMVHW if unaligned geared synchro or step 1Hz Rate of turn TIROT if r...

Страница 24: ...R LF nnn n offset angle 0 360 Output data Status PSTOC R CR LF equal to calibration running PSTOK C CR LF equal to calibration completed or not running as presented before start calibration PSTOK F CR LF equal to calibration failed time out Data transmission Baud rate 4800 Data bits 8 Parity None Stop bits 1 Busse Yachtshop de info busse yachtshop de ...

Страница 25: ... simrad it MALTA Medcomms Ltd 4 Msida Rd Gzira GZR03 Tel 356 21 335521 Fax 356 21 310820 NORWAY Simrad Marine AS Joh Berentsensvei 109 P O Box 53 Laksevåg N 5847 Bergen Tel 47 55 94 10 00 Fax 47 55 94 10 05 www simrad no POLAND Escort Ltd Electronics Syst Ul Energetyków 9 70 656 Szczecin Tel 48 91 462 4379 Fax 48 91 462 4408 www escort com pl PORTUGAL Nautel Sistemas Maritima Lda Edificio Liscont ...

Страница 26: ...td 9 2 Sakae Cho Kita Ku Tokyo 114 0005 Tel 81 3 3913 2337 Fax 81 3 3913 3479 Shipmate Japan Co Ltd 2 5 4 Fukuura Kanazawa ku Yokohama 236 0004 Tel 81 45 788 2731 Fax 81 45 788 2732 TAIWAN Dragon Elephant Enterprise Co Ltd 12F 4 No 251 Min Chuan 1st Road Kaohsiung Taiwan ROC Tel 886 722 72887 Fax 886 722 72910 AMERICAS CANADA Simrad Canada Ltd P O Box 397 112 Lincoln Street Lunenburg Nova Scotia C...

Отзывы: