Installation
20220505H
59
LINEAR DRIVE UNITS
MODEL MOTOR
VOLTS
JUNC-
TION
UNIT
MAX
STROKE
mm (in.)
PEAK
THRUST
kg (lb.)
MAX
RUDDER
TORQUE
Nm
(lb.in.)
HARD-
OVER
TIME
sec.
(30% load)
PWR.
CON-
SUMP.
TILLER
ARM
mm
(in.)
MLD200 12V
J3000X
300
(11,8)
200
(440)
490
(4350)
15 1,5-6
A
263
(10,4)
HLD350 12V
J3000X
200
(7,9)
350
(770)
610
(5400)
12 2,5-8
A
175
(6,9)
HLD2000L 12V
J300X
340
(13,4)
500
(1100)
1460 (12850)
19
3-10 A
298
(11,7)
HLD2000D 24V
J300X
200
(7,9) 1050
(2310)
1800
(15900)
11 3-10
A
175
(6,9)
HLD2000LD 24V J300X
340
(13,4) 1050
(2310)
3180
(28000)
19 3-10
A
298
(11,7)
MSD50* 12V
J3000X
190
(7,5)
60
(132)
– 15
0,8-2
A
–
Steering gear interface: Connects to quadrant or tiller.
* For stern drive power assisted steering only.
1.
The motor voltage is stepped down by the junction unit when
operating from 24V or 32V mains (except for RPU1 and
RPU3).
2.
The specified junction unit is necessary to achieve max drive
unit capacity.
3.
Recommended operational thrust or torque is 70% of listed
value.
4.
Typical average power consumption is 40% of listed
maximum value.