Simrad AP20 Autopilot
104
20220505H
Exit the Display Units menu by pressing STBD [>] button to
proceed to the Master Reset menu, or press STBY to return to
normal AP20 operation.
Master Reset
Language
Dockside
Interface
Seatrial
Parameters
NMEA Test
Display
Master Reset
SW V1R3
May 14 2002
09:38 0 00
No
Yes
Note !
A Master Reset is part of the final test at factory and will reset
the memories to factory settings. Unless you need to clear all
stored values during the installation setup procedure, you should
not perform a Master Reset. Master reset will also clear
compass calibration values stored, except for RFC35R Rate
compass where values are stored in the compass.
The Master Reset needs a double confirmation to prevent an
unwanted reset. To perform a Master Reset, rotate the course
knob clockwise and observe the display; then rotate the course
knob counter clockwise.
Exit the Installation Menu by pressing STBY to return to normal
AP20 operation.
Final sea trial
After having completed all settings in the Installation Menu, take
the boat out and perform a final sea trial in open waters with
sufficient distance to other traffic.
•
Steer the boat on all cardinal headings in AUTO mode.
•
Start with low and medium speeds to get familiar with the
response from the AP20.
•
Try the effect of LO and HI speed settings.
•
If the hardware for automatic HI/LO speed selection is
connected and configured, verify that the HI/LO transition is
occurring, and the HI/LO parameters are changing after the