56
922-20297011/1.0
a
Position one person at each end of the cable.
b
Establish good communications via two-way communication devices.
c
Ensure that the cable is not connected to any power source.
If a cable terminates in a plug at the unit, disconnect the plug to conduct the test
more easily.
d
Select one pair of cable cores and verify that the cores are connected to the correct
terminals in the unit.
e
Connect your ohmmeter to the two terminals and check the continuity.
A low resistance between the two cores may indicate a connection to circuits or
units with low internal resistance. Disconnect the cores from the terminal block
and test again. The resistance should be nearing open circuit.
f
Tell the other person to short the two cores together using the shorting strap.
g
Using your ohmmeter, check the continuity again.
The resistance should now be zero ohms.
h
Tell the other person to remove the shorting strap.
Verify that the resistance reaches open circuit again.
i
Check each core’s resistance to ground, and each core’s resistance to all the other
cores in the cable.
All results should be close to open circuit.
j
Reconnect the cores to the terminal block (if they were removed).
k
Move on to the next pair of cores and repeat the continuity test until the entire
cable has been checked.
Further requirements
You are now ready to power up the M3 Sonar FLS for the first time.
Related topics
M3 Sonar FLS Installation Manual
Содержание M3 Sonar FLS
Страница 1: ...Installation Manual M3 Sonar FLS Forward Looking Multibeam sonar ...
Страница 2: ......
Страница 8: ...6 922 20297011 1 0 M3 Sonar FLS ...
Страница 72: ...70 922 20297011 1 0 Sonar Head outline dimensions M3 Sonar FLS Installation Manual ...
Страница 73: ...922 20297011 1 0 71 Drawing file ...
Страница 97: ......
Страница 98: ... 2020 Kongsberg Mesotech ...