Procedure
1
Remove the o-ring from the Cable Connector Plug.
Use the Parker o-ring picks to extract the o-rings from the Cable Connector Plugs and
Flanged Connector Receptacle.
2
Clean the o-ring surface with Q-Tips and Isopropyl Alcohol.
Ensure all dirt, hair, and debris is removed from the o-ring surface.
3
Inspect the o-ring for defects.
Be sure to keep the o-ring free of dirt, hairs, or other contaminants.