HPR 400 Transceiver Unit
10
130314 / F
CABLING
General information
All cables to and from the transceiver unit are terminated in
plugs on the rear of the unit.
If the transceiver unit is mounted in a rack, operator console or
other unit mounted on shock absorbers, ensure that 10 cm of
slack cable is provided outside the cabinet to allow the unit to
move on its shock absorbers without damaging the cable.
Ensure that a “service loop” of approximately 15 cm of slack
cable is provided inside the cabinet to allow for future
maintenance of the unit.
References
Refer to the Cable Layout and interconnections section for the
cable terminals and connections.
Procedure
1
Select one cable.
2
Referring to the Cable gland assembly procedure given in
the Cable layout sections, prepare the end of the cable.
- Cable glands are only required if the cables are pulled
through cabinets sides or bottom plates.
3
Referring to the Cable layout section, introduce the cable
into its designated cable gland in the bottom of the
cabinet.
- Ensure enough slack is left in the cable to permit
alterations, maintenance etc.
4
Assemble the cable gland.
5
Connect the cores into the relevant terminals on the plug.
Insert the plug into the socket.
6
Check all wiring, especially the power supplies, before
switching power onto the unit.
Transducer cable connection
1
Remove the protective cover from the connector on the
cable.
2
Align the connector with the socket on the transceiver
unit, then carefully press the connector into the socket.
- Ensure the pins are not damaged.
3
Tighten the securing screws to hold the connector firmly
into the socket.