64
378511/A
CBMF board
R
E
External
power
cd020104_102_002
100
Ω
RTS out+
Trig out+
RTS out-
Trig out-
Customer
input
Power
Resistor value
Minimum effect
5 V
0.38 kΩ
0.1 W
12 V
1.08 kΩ
0.15 W
24 V
2.28 kΩ
0.25 W
Note
To avoid ground loops and damage of the EM 2040 electronics caused by external
connections, all connections are optically isolated.