background image

INSTRUCTION MANUAL

ACS500

Acoustic Control System, Gisma testport system

Содержание ACS500

Страница 1: ...INSTRUCTION MANUAL ACS500 Acoustic Control System Gisma testport system...

Страница 2: ......

Страница 3: ...Kongsberg ACS500 Acoustic Control System Instruction Manual Gisma test port system 397128 C July 2016 Kongsberg Maritime AS...

Страница 4: ...ithout the written approval from Kongsberg Maritime AS Disclaimer Kongsberg Maritime AS endeavours to ensure that all information in this document is correct and fairly stated but does not accept liab...

Страница 5: ...Installing the Subsea Control Unit 20 INSTALLING THE SUBSEA TRANSDUCER 21 Installing the subsea transducer 21 CABLE LAYOUT AND INTERCONNECTIONS 23 Cable plan 24 List of cables 26 Cable procedures 27 C...

Страница 6: ...ery level 45 Battery status Acoustic Command Unit 45 Battery status Subsea Control Unit 45 External battery capacity 45 User settings 46 Setting the telemetry power level for the ACU 46 Setting the te...

Страница 7: ...th HiPAP 72 MAINTENANCE 74 Acoustic Command Unit 75 Cleaning the Acoustic Command Unit 75 Charging the Acoustic Command Unit 75 Changing the battery on the Acoustic Command Unit 76 Dunking transducer...

Страница 8: ...97 Subsea Control Unit battery 97 Subsea Control Unit top end cap 97 Subsea Control Unit vent screw for top end cap 97 Subsea Control Unit maintenance kit for top end cap 98 Subsea Control Unit brack...

Страница 9: ...utline dimensions 112 Subsea Control Unit outline dimensions 113 Subsea Control Unit arrangement 114 Subsea Control Unit bracket 115 TDR30V 34GT Subsea transducer outline dimensions 116 External quad...

Страница 10: ...ve opens 130 Opening a transponder with defect possible defect battery 131 Opening a functioning transponder 131 Handling heated or warm separate battery 131 Handling transponders and separate transpo...

Страница 11: ...ngsberg ACS500 Registered trademarks Windows Windows XP and Windows 7 are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries HIPAP is a reg...

Страница 12: ...to familiarize yourself with the Kongsberg ACS500 Topics System description on page 11 System diagram on page 12 System units on page 14 List of parts on page 16 General supply conditions on page 16...

Страница 13: ...n ACS500 is designed for optimal control of subsea valves and is rated to 4000 metre depth ACS500 may be used to control an blow out preventer system as an emergency system or other subsea valve contr...

Страница 14: ...Kongsberg ACS500 System diagram A standard ACS500 system diagram is provided System with y split cable 12 397128 C...

Страница 15: ...ACS500 System with interface cables 397128 C 13...

Страница 16: ...h proof portable case The ACU has an internal rechargeable battery with approximately 10 hours of continuous operation on a fully charged battery The customer also have the option of using the ACU as...

Страница 17: ...lectric signal applied to the transducer Subsea Control Unit The SCU is the unit controlling the subsea valves Commands are sent from the ACU via the transducers and sent from the SCU to the valves Fi...

Страница 18: ...nt during unpacking All equipment must be inspected for physical damage i e broken controls and indicators dents scratches etc during unpacking If any damage to the equipment is discovered the recipie...

Страница 19: ...s been installed onto Unless other arrangements have been made in the contract the Kongsberg ACS500 guarantee period as specified in the contract begins when the acceptance documents have been signed...

Страница 20: ...necessary to plan the installation of the Kongsberg ACS500 according to Kongsberg Maritime s requirements Correct installation is vital to the system performance See your registration form for all pa...

Страница 21: ...try and corresponding maritime authority and or classification society The shipowner and shipyard performing the installation are responsible for obtaining and paying for installation approval Kongsbe...

Страница 22: ...the SCU Procedure 1 The SCU comes secured on a mounting bracket See the Drawing file on page 110 Mount the bracket onto the valve control structure by the hooks behind the SCUs The bracket is constru...

Страница 23: ...e sides of the valve package and must be positioned such that they have a clear line of sight to the surface They should be located as far away from the valve structure and other reflective surfaces a...

Страница 24: ...Kongsberg ACS500 4 Tighten the bolts to the torque recommended by the bolt manufacturer If A4 or similar bolts are used tighten the bolts to a torque of 40 Nm 22 397128 C...

Страница 25: ...ons Cable layout and interconnections This chapter provides the cable plan and cable installation requirements for the Kongsberg ACS500 Topics Cable plan on page 24 List of cables on page 26 Cable pro...

Страница 26: ...Kongsberg ACS500 Cable plan Observe the cable plan for Kongsberg ACS500 All cables are provided from Kongsberg Maritime System with y split cable 24 397128 C...

Страница 27: ...erconnections System with interface cables A Dunking transducer with cable drum B Acoustic Command Unit C Subsea Control Unit D Subsea Transducer E Customer valve package F Quad battery pack G Field s...

Страница 28: ...Subsea Control Unit and is 2 metres long C5 Subsea battery cable optional This cable is identical to C4 C6 Transducer test cable This cable is for testing in air is 50 metres long and on a cable drum...

Страница 29: ...purposes and to allow for vibration make sure that some slack is provided for each cable Topics Connecting the cable from the Subsea Control Unit to the external quad battery unit option on page 28 C...

Страница 30: ...y to prevent the cables being damaged 4 Connect the cable to the SCU as indicated Connect the other end to the external battery unit These are cables ACS500 C4 and ACS500 C5 Connecting the transducer...

Страница 31: ...ect the cable to the SCUs as indicated Connect the other end to the valve package This is cable ACS500 C10 Connecting the interface cable from the Subsea Control Unit to the valve package Purpose This...

Страница 32: ...drum on page 30 Starting operation on page 31 Dunking transducer with cable drum A Locking clip open B Bars C Locking clip closed D Cover E Cable connection 1 5 metres F Handle G Drum lock Opening th...

Страница 33: ...ace the transducer in the basket 6 Lock the transducer cable by pushing the drum lock G in 7 Fold in the handle F 8 Press the two bars B together and press the locking clip C into position Starting op...

Страница 34: ...edure 1 Place the ACU in a suitable location and open the lid by pressing the handle knobs and pulling the handles towards you 2 Turn on the ACU with the Power button D on the right hand side The syst...

Страница 35: ...page 48 3 In the SCU Solenoid Information section tap the function you want to execute 4 Press Execute F on the left side of the ACU and tap Execute N on the touch screen at the same time 5 Observe th...

Страница 36: ...Kongsberg ACS500 Acoustic Command Unit This chapter contains detailed descriptions of the ACS500 control panel 34 397128 C...

Страница 37: ...e with the Emergency button to start an emergency sequence G Trackball and mouse controls for operational use H This will only turn off the computer the hardware will still drain the battery Use butto...

Страница 38: ...Kongsberg ACS500 ACU Computer buttons on page 37 User interface on page 38 36 397128 C...

Страница 39: ...puter off without saving any changes Use the Power button D Power button and battery level The battery level indicator M shows you how much battery power is left A green LED is lit when you have full...

Страница 40: ...Status on page 40 Battery status on page 40 Sensor Input on page 41 More Status on page 41 Help on page 42 Subsea Telemetry Power on page 42 Execute on page 42 SCU Solenoid Information on page 42 Exi...

Страница 41: ...mplete system Menu bar SCU 1 and SCU 2 are the operational menus for the two Subsea Command Units and are explained in detail in Operational procedures on page 43 Operation Log is where all commands a...

Страница 42: ...igure the different options in your system System Status Tap Read to see the system status It is important to know the status of the system before executing any commands Battery status Tap Read to see...

Страница 43: ...he reading comes up and the colour of the field indicates if the values are within the set parameters Alarm conditions are shown in red and a dialogue comes up with the alarm details More Status Tap M...

Страница 44: ...Choose between Minimum Low High and Maximum Tap Set to confirm the setting Execute Execute is used for valve operation and in the two hands two buttons emergency system SCU Solenoid Information This s...

Страница 45: ...ge 51 Messages on page 54 Valve operation Purpose This procedure shows how to start up the subsea system The system is delivered with the batteries separate as a safety precaution Procedure 1 Select t...

Страница 46: ...n is done Dark green The valve operation is done and the system has sent a warning the warning is displayed by the valve symbol Low battery or High currents are examples of warnings Red An error happe...

Страница 47: ...ed when the battery is almost empty See Acoustic Command Unit on page 34 Battery status Subsea Control Unit Purpose This procedure helps you find the battery level of the SCU Procedure 1 In the ACU ta...

Страница 48: ...n page 47 Changing between Cymbal and FSK on page 47 Setting the telemetry power level for the ACU Purpose This procedure explains how to change the power level for the ACU Procedure You should always...

Страница 49: ...er level on 2 In the Subsea Telemetry Power section use the arrows to change the power setting 3 Tap Set to confirm the setting 4 A telemetry dialogue will come up and show if the power level is chang...

Страница 50: ...e step at the time on both the ACU and the SCU See Setting the telemetry power level for the ACU on page 46 and Setting the telemetry power level for the Subsea Control Unit on page 47 Check the commu...

Страница 51: ...sors are checked and listed When the values are within the predefined parameters the slot is green When the values are outside the limits you receive an alarm message Reading the software versions Pur...

Страница 52: ...quence that can be performed in the event of Windows not working Procedure 1 Unscrew the button on the emergency button cover E 2 Observe the LEDs inside if the Run LED is red you have an error The em...

Страница 53: ...the session Auto Shutdown option The Auto Shut Down system is a predefined automated shutdown sequence When the sensors are in a predefined state the system will close the predefined valves in a prede...

Страница 54: ...ce in the example with 4 single valve operations will be executed directly after triggering from the sensors from SCU 1 The SCU 2 will perform a defined delay before starting the ASHD valve sequence t...

Страница 55: ...Operational procedures The main window in the ACU will display information about the Auto Shutdown status The status window will either show Auto Shutdown as Enabled or Disabled 397128 C 53...

Страница 56: ...o status reply after execution of a valve on page 65 Case 4 Trying to activate the Arm function twice on page 66 Case 5 Executing a Disarm function when a valve function is still active on page 66 No...

Страница 57: ...rigger an active valve directly Check for sensor failure Analogue sensor error detected SCU error bit message regarding Analogue Sensor connection Check the SCU BOP Interface and Sensor Current low li...

Страница 58: ...essage is displayed then the SCU is not allowed to perform a Valve operation towards the solenoids Try to read the actual current value in More Status Check battery status If possible check the other...

Страница 59: ...enient for battery change Sensor input Output values available may be configured in different ways mA Psi etc Normal current sensor values should be in the area of 4 to 20 mA The background colour wil...

Страница 60: ...eakage value Valve operation messages Message Description Action Press execute buttons When choosing a Valve function we get this message in order to proceed in the process Press the two Execute butto...

Страница 61: ...ll be updated with a warning message Check current reading valve in More status If the valve is significantly outside the defined scope then check the SCU system Unknown This valve has not been operat...

Страница 62: ...fore checking out the problem Possible solution Repeat the DISARM function in order to reset all Valves Not armed Force red colour Text and colour when main status of SCU has discovered an VALVE ERROR...

Страница 63: ...nt detected Check SCU function if repetition of the message then prepare for service exchange of unit Low battery Status message bit from SCU Low battery event detected Check Battery status remaining...

Страница 64: ...ed Current overflow Caution Fatal Error detected SCU will not execute the Valve function due to current overflow in the system in order to protect the SCU electronics and the solenoids Try to read the...

Страница 65: ...e is not within specified window showing either a Low or High current warning The actual current value may be checked in the More Status menu Valve 5 ARM and DISARM functions were executed OK When try...

Страница 66: ...ed from the SCU Valve 5 execution is stopped with a yellow warning Valve already executed Force This message occurs when the previous status from the readback sensor in the SCU is that Valve 5 is alre...

Страница 67: ...U giving a warning Timeout Force Note In a critical operational phase we may still try to execute the function in Cymbal only regarding timeout window setup values without receiving any status read ba...

Страница 68: ...readback sensor indicates that the valve package is already armed This is only a yellow warning Press and tap both execute buttons for 5 seconds in order to perform the function Case 5 Executing a Dis...

Страница 69: ...ue to unwanted execution of the active valves in the system When trying to execute the DISARM function when ARM sensor is not Active we get a red background for status Not armed Force on the valve DIS...

Страница 70: ...S500 Simulation and test This chapter describes the test procedures for the ACS500 system Topics Connecting the test equipment on page 70 Test procedure on page 70 Testing ACS500 with HiPAP on page 72...

Страница 71: ...Simulation and test 397128 C 69...

Страница 72: ...rred method Purpose This procedure shows how to set up the test system Procedure 1 Disconnect the subsea transducer from the SCU 2 Connect the transducer test cable to the SCU 3 Connect the other end...

Страница 73: ...When the LED is switched off check that the correct status message is displayed on the ACU screen FAILURE is displayed if something is wrong 6 Continue with the ARM function if available Tap ARM and...

Страница 74: ...Kongsberg ACS500 Testing ACS500 with HiPAP Testing the system is also possible using HiPAP 72 397128 C...

Страница 75: ...Connect the transducer patch cable 2 Lower the dunking transducer into water Caution Make sure there are no obstacles between the dunking transducer and the HiPAP transducer 3 Operate the system from...

Страница 76: ...the main units Note Major repairs and complete overhaul of the Kongsberg ACS500 can only be done by an authorized Kongsberg Maritime service engineer Topics Acoustic Command Unit on page 75 Dunking t...

Страница 77: ...cloth moistened in fresh water Do not use strong solvents Dedicated cleaning chemicals for displays are provided by office suppliers Charging the Acoustic Command Unit Purpose This procedure explains...

Страница 78: ...pends on use and battery maintenance Procedure 1 Detach the supports on either side of the lid by unscrewing one screw on each side 2 Unscrew 18 screws on the front panel 3 Lift the monitor from the c...

Страница 79: ...nsducer Purpose This procedure explains how to check the dunking transducer for defects Procedure 1 Ensure that the transducer face is clean and free of defects 2 Check that the retaining strap is in...

Страница 80: ...lastic scraper or a stiff brush not wire to remove shells and growth Be careful not to damage the paint as this leads to corrosion 2 Ensure that all dirt slime and growth is removed 3 Clean the unit t...

Страница 81: ...vent screw and the top end cap itself when the lid has been opened See Testing the seal on page 89 Replace a Subsea Control Unit and duplicate the configuration Purpose This procedure explains how to...

Страница 82: ...ou want to duplicate in the Replace SCU dialog box 10 Select communication port 11 Select report location 12 Select the Configure and Execute at the same time this is a two hand operation Wait while t...

Страница 83: ...ert the new battery Inserting the battery at an angle makes it easier 4 Place the top end cap back on Observe the alignment marks on the lid and the body of the SCU Follow the open procedure in revers...

Страница 84: ...to identify the interseal test ports to verify that the SCU is properly sealed and watertight Related topics Interseal test on page 88 Important Before you apply pressure make sure that all connection...

Страница 85: ...testing see Testing the seal on page 89 External quad battery unit for the Subsea Control Unit Maintenance on the quad battery unit is mostly changing the battery and checking the seals before the un...

Страница 86: ...e unit before opening it Procedure 1 Use a wooden or plastic scraper or a stiff brush not wire to remove shells and growth 2 Ensure that all dirt slime and growth is removed 3 Clean the unit thoroughl...

Страница 87: ...t on the test port D when the lid has been opened See Testing the seal on page 89 Changing the batteries in the external quad battery unit Purpose This procedure explains how to change the battery on...

Страница 88: ...growth on the transducers will degrade the system s operational capabilities Clean the transducers at every opportunity Procedure 1 Use a wooden or plastic scraper or a stiff brush not wire to remove...

Страница 89: ...bolts are not delivered with the transducer as they depend on the thickness and material of the structure they are mounted on 10 Tighten the bolts to the torque recommended by the manufacturer 11 Run...

Страница 90: ...nnect to Digital pressure indicator C Volume adjuster D Limit adjuster E Scissor action handles F Outlet port connect to unit to be tested G Selector valve H Pressure relief valve Assemble the test ki...

Страница 91: ...essure indicator user manual Druck PV411A Hand pump user manual Assemble the test kit on page 88 Important Before you apply pressure make sure that all connections are correct and that all equipment a...

Страница 92: ...This verifies that the seal is undamaged 12 Open the selector valve G carefully to remove the pressure by turning counterclockwise Changing the battery in the Digital pressure indicator Purpose This p...

Страница 93: ...Maintenance 4 Connect a new 9 volt battery and assemble everything in the reverse order 397128 C 91...

Страница 94: ...ne replaceable units are defined Additional spares are also identified Topics Line replaceable units on page 93 Ordering spare parts on page 94 Acoustic Command Unit spare parts on page 94 Dunking tra...

Страница 95: ...ned as line replaceable units for the SCU Subsea Control Unit Complete unit Battery Top end cap Complete top end cap with O rings Vent screw Complete with O ring Top end cap maintenance kit All O ring...

Страница 96: ...nits printed circuit boards and software the vessel name is also useful as this allows us to update our vessel database Acoustic Command Unit spare parts All spare parts for the ACU are listed here Ac...

Страница 97: ...arts All spare parts for the dunking transducer are listed here Dunking transducer line replaceable units on page 95 Dunking transducer complete unit on page 95 Dunking transducer line replaceable uni...

Страница 98: ...spare parts for the SCU are listed here Subsea Control Unit line replaceable units The following parts have been defined as line replaceable units for the SCU Subsea Control Unit Complete unit Battery...

Страница 99: ...form for part number information Subsea Control Unit battery Item information Part name Lithium battery pack Part number 319554 Subsea Control Unit top end cap Item information The top end cap is del...

Страница 100: ...cable Item information Part name Y split cable Gisma 37 pins connector YC G37T 2 11 G37T Part number 336621 Part name Y split cable Gisma 37 pins connector YC G37T 2 5 G37T Part number 392179 Part nam...

Страница 101: ...8 G37T Part number 394986 Subsea Control Unit serial line cable Item information Part name SL A6 5 G7T Part number 397127 Subsea Control Unit sealing cap for 7 pins connector Item information Part nam...

Страница 102: ...ete unit Item information Part name Subsea transducer TDR30V 34GT Part number 336611 Subsea transducer transducer cable Item information Part name Transducer cable XC G7T 15 G7T Part number 336622 Tes...

Страница 103: ...mulator test cable Part number Customer specific see the registration form Patch cable for testing with HiPAP Item information Part name Patch cable Part number 336625 Transducer test cable Item infor...

Страница 104: ...nit may be any large or small part of the system It can be supplied as part of the initial delivery or as a spare part Topics Disposal on page 103 Inspection on page 103 Lifting on page 103 Re packagi...

Страница 105: ...bserve the relevant Waste Electrical and Electronic Equipment WEEE regulations Inspection An inspection must be carried out immediately after the unit s have arrived at their destination 1 Check all w...

Страница 106: ...ontainer by appropriate shock absorbing insulation polystyrene foam chips etc Large units must be placed in a suitable cardboard box or wooden crate The unit must be protected against physical damage...

Страница 107: ...areas must be cleaned prepared and preserved using the correct preservation mediums for the unit The mediums to be used will usually be defined in the units maintenance manual 3 Open the unit and usi...

Страница 108: ...the electronic components as dry as possible Coatings Spray the unit externally with a corrosion inhibitor e g a light oil before packing Storage prior to installation or use When a system a unit or...

Страница 109: ...If the unit contains normal batteries these may have been disconnected isolated before the unit was packed These must only be reconnected before the installation starts Units containing batteries are...

Страница 110: ...ls door keys etc Unpacking electronic and electromechanical units Electronic and electromechanical units will normally be wrapped in a clear plastic bag Lift the unit in its bag out of the carton and...

Страница 111: ...s must be investigated by the packer shipper before the unit is dispatched All local transportation must be carried out according to the same specifications as for the initial delivery In general all...

Страница 112: ...e available on PDF and or AutoCad s DWG format Dunking transducer unit outline dimensions on page 111 Acoustic Command Unit outline dimensions on page 112 Subsea Control Unit outline dimensions on pag...

Страница 113: ...Drawing file Dunking transducer unit outline dimensions 397128 C 111...

Страница 114: ...Kongsberg ACS500 Acoustic Command Unit outline dimensions 112 397128 C...

Страница 115: ...Drawing file Subsea Control Unit outline dimensions 397128 C 113...

Страница 116: ...Kongsberg ACS500 Subsea Control Unit arrangement 114 397128 C...

Страница 117: ...Drawing file Subsea Control Unit bracket 397128 C 115...

Страница 118: ...Kongsberg ACS500 TDR30V 34GT Subsea transducer outline dimensions 116 397128 C...

Страница 119: ...Drawing file External quad battery unit for SCU outline dimensions 397128 C 117...

Страница 120: ...Kongsberg ACS500 Simulator outline dimensions 118 397128 C...

Страница 121: ...o 336676 Lubricants Use Molykote 1 11 or Parker Super O Lube for O rings O ring handling Use O ring pick tool 372654 for gentle O ring handling Test port torque Tighthening torque for lubricated plug...

Страница 122: ...g we are continuously working to improve the quality and performance of our products Technical specifications may therefore be changed without prior notice Topics Acoustic link on page 121 Performance...

Страница 123: ...mpleted Two basic link principles are available in the UTB modems The optimal and fast Cymbal spread spectrum coherent acoustic link The well known non coherent FSK principle with a number of transmit...

Страница 124: ...0 kHz to 26 5 kHz in steps of 250 Hz Wake up frequencies FSK Channel 76 24 and 23 5 kHz Wake up frequencies FSK Channel 86 24 5 and 23 5 kHz Max transmission power 300 W Common for transducers Operati...

Страница 125: ...19 5 kg Dunking transducers Width 225 mm Height 500 mm Depth 590 mm Weight Approximately 25 kg TDR30V 34T Diameter 166 mm Height 212 mm Weight 15 kg External quad battery Diameter 304 mm Height 947 5...

Страница 126: ...cells Lithium Battery output 14 VDC Total battery energy content Maximum 4 x 128 Ah Environmental specifications This section provides the technical specifications and requirements related to the envi...

Страница 127: ...and separate lithium batteries Identification of the products and company Product name All Kongsberg transponders Subsea Control Units with a lithium battery and separate Kongsberg transponder lithium...

Страница 128: ...port website http www km kongsberg com support_hpr Composition and information on chemicals Battery chemicals A transponder lithium battery consists of Lithium Metal cells with the formula Lithium Thi...

Страница 129: ...nschein SL 780 Saft LS 33600 Saft LSH 20 Sonnenschein SL 760 Battery design A transponder lithium battery consists of several battery cells that are electrical connected both in serial and parallel Th...

Страница 130: ...ide the transponder The transponder can explode if the inside pressure is high enough If the transponder explodes either the transducer or the bottom end cap will blow out or the transponder becomes f...

Страница 131: ...al reactions fire will continue without additional supply of oxygen so extinguisher like Lith X will not work properly Applying water directly onto a battery may develop hydrogen gas due to the possib...

Страница 132: ...emperature must be checked to verify a possible temperature increase in the lithium battery Failing and normal temperature Take out the battery see Opening a transponder with defect possible defect ba...

Страница 133: ...ction equipment Caution Do not stand in front of transducer or bottom end cap when opening the transponder If there has been water ingression and the battery is still warm Disconnect the battery from...

Страница 134: ...stored indoors The battery must be removed from the transponder when stored indoors Storage temperature Recommended storage temperature lies between 0 C and 25 C max 50 C min 55 C Storage relative air...

Страница 135: ...ity The products are stable under normal conditions see Hazards identification on page 127 Toxicological information Signs and symptoms None unless battery ruptures In the event of exposure to interna...

Страница 136: ...be shipped in accordance with the prevailing national regulations Transponder with lithium battery UN no 3091 Class 9 Miscellaneous Lithium batteries contained in equipment Separate transponder lithi...

Страница 137: ...afety procedures Other information The battery cell manufacturers safety data sheets are available on the following internet addresses Saft www saftbatteries com Tadiran Sonnenschein www tadiranbatter...

Страница 138: ...Kongsberg ACS500 Appendix A Type approval certificate 136 397128 C...

Страница 139: ...Appendix A Type approval certificate 397128 C 137...

Страница 140: ...Kongsberg ACS500 138 397128 C...

Страница 141: ...Appendix A Type approval certificate 397128 C 139...

Страница 142: ...Kongsberg ACS500 140 397128 C...

Страница 143: ...h GISMA foam cleaner Allow three minutes to react In case of strong dirt repeat the procedure Then rinse with clean water Following rinse with the enclosed cleaning liquid to neutralize foam cleaner 3...

Страница 144: ...g gegen die Einbaudose Schottdurchf hrung oder Druckk rperdurchf hrung geschraubt werden Besitzt die berwurfmutter eine Blockierschraube so muss diese angezogen werden After tightening the coupling nu...

Страница 145: ...r change battery 90 Disposal equipment 103 DNV certificate 137 drawing simulator outline dimensions 118 Drawing ACU outline dimensions 112 dunking transducer outline dimensions 111 O rings for test po...

Страница 146: ...Maintenance 74 procedures 74 Maritime authority approval 19 Mechanical drawings 110 Menu bar 39 More status 41 N Normal operation 33 43 Valves 33 43 O Online help 42 Open quad battery 84 Open SCU 78 O...

Страница 147: ...ea Command Unit cloning 79 duplication 79 Subsea Control Unit change battery 81 installation 20 Line replaceable units 93 96 open 78 Power level 47 Subsea telemetry power 42 Subsea transducer change 8...

Страница 148: ...2016 Kongsberg Maritime...

Отзывы: