KONE MonoSpace®
Maintenance Instruction
© 2006 KONE Corporation
All rights reserved.
Disclosure prohibited
D.4
Main Contactor Led is OFF or blinking
Step
Check
Possible cause
Action
1
LOPCB Main Contactor Led
is on for a while but
LCE230 / LCEADO main
relay Led (V1) is OFF all the
time?
Hint:
LCEADO/V1 Led
indicates that both LCE and
drive enable the main
contactor.
LOPCB/Main Contactor Led
indicates that LCE enables
the main contactor.
Some drive supervision
prevents the drive from
enabling the main contactor.
Check the fault log to locate the
problem (when the fault code is
on menu display, press Select
to see subcodes).
The drive or the flat cable
between LCE and drive could
be defective.
Replace the defective
component.