D.3
Shaft Door Contact Led is OFF (F0051)
Step
Check
Possible cause
Action
1
No 230VAC voltage
at LOP230/XLH8 pin
3?
Defective switch or contactor.
At each floor:
Check the cables and
the landing door
contacts.
2
230VAC voltage at
XH2 pin 3 on
LCE230 / LCEADO
board when the
elevator is in RDF
mode and Inspection drive is
not activated?
Defective LCE230 / LCEADO,
LCECPUnc or flat cable
between boards.
Replace the defective
cable if necessary.
Replace boards one by
one to find the defective
board.