KONE MonoSpace®
Maintenance Instruction
© 2006 KONE Corporation
All rights reserved.
Disclosure prohibited
A.4
LOP230/F2 OK Led is OFF but F2 fuse is OK
Step
Check / Symptom
Possible cause
Action
1
No 230VAC
voltage at
LOP230/XLH1
pins 1-2 and
no 400VAC voltage at
LCEREC/X1 connector in the
SEP panel?
Defective or loose cables
between main switch 220
and LCEREC/X1.
Fix the loose cables.
Replace the damaged
cables.
2
No 400VAC
voltage at
LCEREC/X2?
F6 or F7 fuse is blown.
Replace the blown fuse.