Adjusting door operator control
Board 1Ø4
®
Adjust door operator control Board 1Ø4
®
as follows.
■
Measure current (optional)
■
Set potentiometers
■
Adjust door speeds
■
Adjust door closing force
■
Adjust nudge speed
■
Set microswitch cams
Board 1Ø4
®
could be damaged if
adjustment instructions are not
followed carefully. If you cannot
complete any of procedures as
described, stop and request
assistance.
A604-017 (2/97)
Toggle switches
To adjust and service door control, use two toggle switches on door operator
control Board 1Ø4
®
— TEST-RUN switch and O-OFF-C switch.
➤
TEST-RUN. TEST-RUN switch is normally in RUN position. When
TEST-RUN switch is in TEST position, it disconnects normal open
and close input signals from door control, and switches the O-OFF-
C toggle switch into the circuit.
➤
O-OFF-C. O-OFF-C switch is normally in OFF (center) position.
OFF position does not indicate input power has been removed. It
only indicates no signal to open or close when TEST-RUN switch is
in TEST position.