5
Place and fix the potentiometer
brackets with the bolts.
6
Reconnect the wires back to their
respective terminals.
7
Place and fix the cover (detached
in Step 3 on page 49), referring
back to page 45.
8
Plug in the power cord and turn ON
the main power switch.
Potentiometer
brackets
Bolts
Black Blue Red
Green
Black
Red
7 Maintenance
Too small
clearance
Correct
Too large
clearance
Make sure both the gears are in
proper mesh with each other.
The fix the potentiometer bracker.
9
Take the steps in “5-1 Checking the game performance” on page 23 and the
steps in “I/O CHECK” on page 25. Follow the procedure below to check the
rifle unit performance.
1 Swing the rifle unit all the way to the left or the right. Hold it in this position.
2 Make sure that the “I” bar in “Volume” of “GUN YAW” is not in the red range.
If in the red range, the potentiometer may get in trouble. Reposition and
readjust the potentiometer so that the “I” bar comes into the green range.
3 While holding the rifle unit in that position, make
sure that the “Free” reading is “0000”.(If the reading
is not “0000”, go back to the above step 1.)
4 Make sure the reading is “0000”, and make one
turn of the potentiometer gear gently by hand.
If the “I” bar in “Free” comes in the red range again,
it means the gear’s clearance is too large. This
fails to play the game. Readjust the potentiometer
gear into good mesh. Finally make sure the “I”
bar is in the green range.
10
Make sure the rifle unit functions as specified. Place and fix the door and
cover (detached in Step 2 and 3 on page 49) with the screws.
4
Содержание GQ830-HD
Страница 12: ...10 CHINESE 10...
Страница 13: ...11 CHINESE 11...
Страница 14: ...12 CHINESE 12...
Страница 15: ...13 CHINESE 13...
Страница 16: ...14 CHINESE 14...
Страница 17: ...15 CHINESE 1 2 3 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 1 4 5 9 10 11 12 13...
Страница 19: ...17 100 mm 3 94 in 100 mm 3 94 in 100 mm 3 94 in CHINESE 816 mm 32 1 in 1800 mm 70 9 in 2040 mm 80 3 in...
Страница 41: ...39 4 Disconnect all the connectors Monitor unit Control unit Connectors 6 Installation and assembling...
Страница 65: ...63 8 Annex FIG 1 UNIT...
Страница 66: ...64 8 Annex FIG 2 UNIT CABINET CONTROL...
Страница 67: ...65 8 Annex FIG 3 UNIT CABINET MONITOR...
Страница 68: ...66 8 Annex FIG 4 UNIT CABINET TITLE...
Страница 69: ...67 8 Annex FIG 5 UNIT RIFLE...
Страница 70: ...68 8 Annex FIG 6 ASS Y SCOPE...
Страница 71: ...69 8 Annex FIG 7 ASS Y BARREL...
Страница 72: ...70 8 Annex FIG 8 UNIT MECHANISM...
Страница 73: ...71 8 Annex FIG 9 ASS Y TRANSFORMER...
Страница 74: ...72 8 Annex FIG 10 ATTACHMENT...
Страница 75: ...73 8 Annex 8 2 Wiring diagram 1 2...
Страница 76: ...74 8 Annex Wiring diagram 2 2...