background image

Summary of Contents for DN 2145

Page 1: ......

Page 2: ...helf Stabilizer 9 Gate Assembly 9 Slide Pusher Assembly 9 PROGRAMMING 10 23 General 10 External Display Items 10 Normal Operation Messages 10 Initial Programming 11 12 Quick Reference Menu Items 13 Service Mode 14 16 Test Mode 16 19 Setup Mode 19 21 Setup Mode 2 21 23 GENERAL MAINTENANCE 24 25 Power 24 Cleaning 24 Eprom Replacement 25 MAJOR COMPONENT DESCRIPTION 26 27 AC Distribution Box Refrigera...

Page 3: ...nergy Star Schematic 48 AC Distribution Box J2 Port Voltages 49 ECC Vender MDB 9 Column Wiring Diagram 50 51 Assembly Domestic AC Distribution Box 52 Assembly Domestic AC Distribution Box T8 Electronic 53 Assembly Export AC Distribution Box CE GS 54 PARTS LIST AND DIAGRAMS 55 89 Machine Front View 1 56 57 Machine Front View 2 58 59 Cabinet Detail 60 61 Lighting Evaporator Fan 62 63 Service Door 1 ...

Page 4: ...rst 4 digits xxxx identify the specific vender The next 4 digits yyyy identify the manufacturing run that the vender was built in The last two alpha characters zz identify the quarter and the year the vender was built The first alpha character identifies the quarter as follows A 1 st Quarter B 2 nd Quarter C 3 rd Quarter D 4 th Quarter The second alpha character identifies the year W 1998 B 2003 X...

Page 5: ...0 Hertz The cabinet serial plate also indicates the amperage of the vender The vender must be plugged into a properly rated single phase alternating current outlet with its own circuit protection fuse circuit breaker DO NOT USE AN EXTENSION CORD GROUND THE VENDER The vender is equipped with a three wire power supply cord and MUST be plugged into a properly grounded outlet DO NOT REMOVE THE GROUND ...

Page 6: ...alism it is recommended that the vender be secured to the floor or wall as described in Dixie Narco Technical Bulletin 344 Due to the large size and weight of the Vender never attempt to move the Vender with a Hand Truck or Stair Climber Use a pallet jack or Vender Cooler Dollies at all times when moving the Vender The vender should never be slid or pushed in place Never side load the leveling leg...

Page 7: ...lux CCM 5G 1 2 3 4 5 The vender will support the following domestic MDB Bill validators Coinco BA 30 B BA 50B Coinco Mag 50 Mars VN 2512 Conlux NBM 3000 Series The vender will support the following MDB card readers Debitek VMC LTD Danyl Schlumberger Fage Diebold Systems Jofemar AT T Campus Wide Evend net Danyl Smartcard The above listed peripherals indicate units that have been tested by Dixie Nar...

Page 8: ... 12 VAC by a transformer Those voltages are sent to the controller via the JI 12 pin connector It also contains 3 fuses that protect the VMC transformer and solenoids The power distribution box also distributes AC power to the lights evaporator fan and refrigeration system which are always energized when the vender is powered up It is located inside the service area mounted to the back wall VENDIN...

Page 9: ...abs of the slide The slide is then installed back into the column GATE ASSEMBLY Can Bottle Trays The gate assembly is mounted on the front portion of the tray assembly and contains the vending mechanism Incorporated in the gate assembly are the front and rear knuckle assemblies as well as the product kicker In standby operation the front knuckle is in the blocking position which holds the front di...

Page 10: ...erature in degrees F To view press the F key then press the key The display will show the vender s inside temperature in degrees F Note This will only display if temperature sensor hardware kit is installed 5 Selection status messages When selecting an item that can not be vended the display will show one of the following a Not Available Until HHMM The selection is blocked under the Not Available ...

Page 11: ...ion 2 first followed by the single selection using option 3 the pricing for the remainder of the shelf would remain and the new price for the single selection would change to the new value Press the CLR key to return to SERVICE MODE POINTS TO REMEMBER Prices entered must not exceed the MAX CREDIT set in the system s program DO NOT press the key when setting prices for individual selections HAPPY H...

Page 12: ...lable times Press the key buttons again and the display will flash DISABLED and return to ITEM Priority will be given to the higher ranked method If one selection on the A tray was set to ENABLE using option 3 above and you wish to change the remaining selections on that tray using option 2 the Setting for the entire tray would take precedence Conversely if the tray was set using option 2 first fo...

Page 13: ...de not available in 030 81 up 5 Date Time 6 Total Sales 7 Health Guard Enabled Disabled 8 Drop Sensor Enabled Disabled 9 Set Cool Time 0 Enter New Password SETUP MODE 2 A Next Item B STS Enabled Disabled C Custom STS Configuration D Default STS Configuration E Display STS Configuration F Set Vend Limit not available in 030 81 up 1 Health Recheck Enabled Disabled 2 Set Retry Limit 3 Sold Out Enable...

Page 14: ... if no time was entered Press the letter E on the keypad and display will scroll SET COOL DOWN Press the key on the keypad and the display will read ITEM There are now three choices 1 Pressing the key will place the entire machine in cool down 2 Pressing a tray selection followed by will place that tray in cool down For example pressing A will place the A tray in cool down 3 Pressing an item selec...

Page 15: ...ver once the minimum vend price line has been met or exceeded The coin return lever will not be inhibited if there is not enough credit to vend the lowest priced item or if a vend failure has occurred Factory setting is FORCE N Press the number 5 on the keypad the display will read FORCE Y or FORCE N depending on the current state Pressing the key will toggle the state Press the CLR key to return ...

Page 16: ...LR key to clear errors When the CLR key is pressed an audible tone will be heard and the display will change momentarily to OK then back to TEST MODE If you wish to exit the list without clearing errors simply push the key and the display will return to list errors If the CLR key is pressed prior to reaching the end of the list the display will jump to END LIST Explanations for the error codes are...

Page 17: ...turn to TEST MODE KEYPAD TEST Press key E Allows the service technician to test any or all keypad keys Press the letter E on the keypad and the display will scroll KEYPAD TEST Press the key and the display will go blank and then press each key on the keypad After each entry the characters will shift into the display from right to left until the CLR key is pressed The display will return to TEST MO...

Page 18: ...Press the A key to scroll through the last 5 openings Press the CLR key to return to TEST MODE POWER OUT Press key 6 Shows the number of times the machine has lost power since last CLEAR TOTALS or MASTER RESET This is a power outage for any reason including the machine being unplugged or the machine s master power switch being turned off Press the number 6 on the keypad and POWER OUT will scroll a...

Page 19: ...SSWORD REQUIRED Allows the service technician to clear any custom idle message and return to the default idle message Press the letter C on the keypad and the display will show CLEAR MESSAGE Press the key and the display will read OK momentarily an audible tone will be heard and then will return to SETUP MODE ENABLE DOLLAR SIGN Press key D PASSWORD REQUIRED Allows the service technician to remove ...

Page 20: ...available in software revisions 030 81 and higher Allows the service technician to set the machine up to dispense a free product on a random basis This mode CANNOT be made item selective If the Winner Mode is set each product in the machine is subject to being dispensed free The winning customer is determined by the program picking a number at random from 1 to the winner mode set number Inputting ...

Page 21: ...e press the letter D on the keypad and the display will scroll SET COOL TIME and then change to COOL 240 Use the keypad to enter the duration of the cool down period that you wish to use Press the key to enter your preferred time into memory The display will read OK momentarily and return to SETUP MODE ENTER NEW PASSWORD Press key 0 PASSWORD REQUIRED Allows the service technician to enter a person...

Page 22: ...der is unable to vend any products from a Space to Sales block the customer s credit will be returned and the entire block will be marked as SOLD OUT Press the F key on the keypad The display will scroll SET VEND LIMIT Press the key while the display is scrolling or wait until the message scrolls off The display will read LIMIT The value is the current vend limit which is applied to each selection...

Page 23: ...ndicate the state of the interval clearing setting Press the number 6 key and INTERVAL CLEARING IS ON or OFF will scroll across display depending on the current setting When ON the interval resettable data to automatically be cleared upon successful completion of a DEX audit When OFF it allows for remote auditing devices that clear resettable data manually to be used to clear the data Press the ke...

Page 24: ...ood detergent or soap mixed in warm water Wax the vender often with a good grade of automobile wax Any corrosion inside the vender should be removed with fine steel wool and the area should be painted with white paint Repair any scratches on painted surfaces to prevent corrosion RECOVERY UNIT Cleaning of the product delivery bin and condenser area requires removal of the product delivery bin To re...

Page 25: ...one is present Remove the Battery clip to allow the Board s memory to drain Leave the clip off for a minimum of 10 minutes Replace the EPROM The EPROM s legs bend easily Remove and replace very carefully Replace the Battery clip and cover if used Apply power to the AC distribution box Go in the Setup Mode and push F for Master Reset Go in the Test Mode and push 0 to clear errors FIGURE 1 EPROM REP...

Page 26: ... REFRIGERATION UNIT DN55 54 DN2145 Roll Up 110 VAC and 220 VAC units Compressor Tecumseh 1 2 HP 115 VAC 60 Hz 1 Phase AK168AT 032 B4 Tecumseh 1 2 HP 220 VAC 50 Hz 1 Phase AK168JT 032 B4 Roll Up unit uses 13 oz of 134A refrigerant Model 1620CA HP T6213Z 220 230 50 Start Relay 110 VAC Tecumseh 90701 220 VAC Tecumseh 90701 1 Double Pole 115 VAC Model 1620CA TI 9660 041 158 Start Capacitor 110 VAC CGE...

Page 27: ...ut to Controller Board from secondary of T1 Fuse X4 Right Side 2 Amp SloBlo protects 12 Volt input to Controller Board from secondary center tap of T1 Varistor Across incoming AC power to remove large power spikes REFRIGERATION UNIT DN35 110 VAC and 220 VAC units Compressor Aspera 1 2 HP 115 VAC 60 Hz 1 Phase T6213Z Unit uses 13 oz of 134A refrigerant Model 1620CA HP T6213Z 220 230 50 Start Relay ...

Page 28: ... ITEM CONNECTION DESCRIPTION 1 J18 Power from AC Distribution Box 2 J17 Vend Sensor 3 J16 Multi Drop Bus 4 J15 Door Interlock Switch 5 J13 Digital Display 6 J12 Temperature Sensor 7 J11 Keypad 8 TRAYS Bottom Row J3 A J4 B J5 C TOP ROW J6 D J7 E J8 7 9 J1 DEX ...

Page 29: ...29 DUAL SENSOR BOARD NON ENERGY STAR ITEM CONNECTION DESCRIPTION 1 J1 Vend Sensor 2 J2 Vend Sensor 3 J3 Jumper from Main Board 4 J4 Temp Sensor On Energy Star only ...

Page 30: ...cturer Recommendation 4 Replace Coin Mech DOLLAR BILL ACCEPTANCE ISSUES PROBLEM CAUSE FIX Bill Validator will not run Prices tube cash conditions Check Mech Tubes Takes Bill in Then Rejects it Check Validator or Replace Stacks Bill While in Escrow Mode Max Price Not Yet Reached Bill Error Listed in Test Mode Communication Error with Bill Validator Bill Validator Reported Error Takes Bill Gives No ...

Page 31: ...FF Disconnected Apply power Blown Fuse Check fuses and replace if necessary Loose connection Check cable at coin mech and controller board Jammed coin mechanism Clear coins Weak springs on changer gate COINCO units only Replace spring Gate partially open Clean and reset gate If COINCO unit check spring Dirty faulty coin sensor Clean Replace Incompatible coin mechanism Replace Defective coin mechan...

Page 32: ...ors to determine cause of Out Of Service Refer to pg 13 for error explanations Loose connection Check cable at bill validator and controller board Coin mechanism low on coins Fill coin tubes Bill path obstructed dirty Clear clean path Wrong option switch settings Reset Incompatible bill validator Replace Defective bill validator Replace Defective controller board Replace ...

Page 33: ...D Incorrect change dispensed Vend prices set incorrectly Check price and reset if necessary Coins not laying flat in tubes Check coin tubes clear and reload coins Defective coin mechanism Replace Defective controller board Replace ...

Page 34: ...om gate removing the weight and use Test Vend to check gate operation Use small amount of WD 40 on pins and recheck Check for bent pins Dirty worn tray insert slide Clean check for flash replace Loose connections Check cable connections at controller board and solenoid Defective solenoid Use Vend Test to check solenoid replace if necessary Defective cable Move cable in question to a new position o...

Page 35: ...ck product door seal and cable openings in cabinet CONDENSATE ON OUTSIDE OF PRODUCT DOOR Condensate on outside of product door Machine in direct sunlight Move machine Machine in location with humidity above 70 Move machine COMPRESSOR WILL NOT STOP Compressor will not stop Defective thermostat Replace ...

Page 36: ...on box Defective door interlock switch Replace Low voltage Check power source Defective thermostat Replace Defective starting component capacitor relay Replace Defective compressor Replace Troubleshooting Tip Use a short 15 Amp extension cord and plug the compressor directly into the wall outlet This will bypass the AC distribution box Note For Testing Purposes Only ...

Page 37: ...ear of cabinet is at least 3 25 82 6 mm from wall Machine in direct sunlight Move machine Faulty product seal Replace Condenser fan or evaporator fan not running Check blade for obstruction Check fan circuit Evaporator is iced up Check for air leaks or clogged condensate drain line Check rear screen for obstructions Ensure rear of cabinet is at least 4 10cm from wall ...

Page 38: ... i Only occurs on one solenoid 1 Defective solenoid 2 Solenoid harness connection ii Occurs on entire shelf 1 Harness issue 2 Defective board 3 Bad AC box 4 Bad electrical service to vender iii Occurs on same column multiple shelves A2 B2 C2 D2 E2 1 Defective board 2 Bad AC box 3 Bad electrical service to vender ii Gate did not rattle or solenoid did not click 1 Software attempted vend a Check err...

Page 39: ...r is enabled product was not detected by drop sensor on a previous vend 1 Ensure software is 030 51 or greater 2 Cycle door to reset sold outs 3 Realign sensor s to catch product 4 Disable drop sensor c Selection is placed under SETUP MODE HEALTH GUARD d Selection is placed under SERVICE MODE SET COOL DOWN function e Selection has been disabled through SERVICE MODE ENABLE ITEM function f SETUP MOD...

Page 40: ...40 DN55 VENDER NON ENERGY STAR Beverage Max Diagram 9 Column ...

Page 41: ...41 DN55 ENERGY STAR VENDER Beverage Max Diagram 9 Column ...

Page 42: ...42 DN35 VENDER NON ENERGY STAR Beverage Max Diagram 6 Column ...

Page 43: ...43 DN35 ENERGY STAR VENDER Beverage Max Diagram 6 Column ...

Page 44: ...44 DN55 35 Compressor Wiring Diagram ...

Page 45: ...45 DN55 DN2145 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC NON ENERGY STAR FIGURE 3 ...

Page 46: ...46 DN55 2145 AC DISTRIBUTION BOX SCHEMATIC EXPORT FIGURE 4 ...

Page 47: ...47 DN35 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC NON ENERGY STAR FIGURE 5 ...

Page 48: ...48 DN55 35 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC ENERGY STAR FIGURE 6 ...

Page 49: ...C VOLTAGES Between Pins Domestic Reading Export Reading 1 2 24 VAC 24 VAC 1 3 12 VAC 12 VAC 2 3 12 VAC 12 VAC 4 9 24 VAC 24 VAC 5 7 115 VAC 220 VAC 6 8 115 VAC 220 VAC AC DISTRIBUTION BOX J2 VOLTAGES ITEM 1 ...

Page 50: ...50 ECC SYSTEM SCHEMATIC RIGHT SIDE MDB SAMPLE ...

Page 51: ...51 ECC SYSTEM SCHEMATIC LEFT SIDE SAMPLE ...

Page 52: ...52 ASSY AC BOX DOMESTIC ...

Page 53: ...53 ASSY AC BOX DOMESTIC T8 Electronic ...

Page 54: ...54 ASSY AC BOX CE GS EXPORT ...

Page 55: ...4 65 Service Door 2 66 67 Service Door 3 68 69 Tall Tray Detail 70 71 Tall Gate Spacers 72 AC Distribution Box Domestic 73 74 AC Distribution Box Export 75 76 Refrigeration Unit DN59 39 Fin Tube Condenser 77 78 Refrigeration Unit DN59 39 Fin Tube Condenser 79 80 Electronics 81 Harnesses 82 83 Labels Decals Misc 84 Screws Nuts 85 86 Washers Bolts Misc Hardware 87 89 ...

Page 56: ...56 MACHINE FRONT VIEW 1 14 6 7 3 5 2 4A 4B 4C 13 10 11 15 8 ...

Page 57: ... 4C Hex Nut 1 4 20 was 900 800 67x x1 800 801 57x x1 4D Strike Plate Service Door 626 030 34x x3 5 Service Door Stop 627 050 42x x3 6 Latch 3 Point Lock 801 305 58x x1 7 Strike Door Lock 3 Point W296 8 DN55 54 35 Leg Assembly Steel Formed 0001 8072 higher 801 305 65x x1 DN2145 Leg Assembly Steel Formed prior to 0001 8072 was W025 1 801 305 66x x1 9 Leg Leveler 5 8 11 x 2 1 16 0001 8072 higher was ...

Page 58: ...58 MACHINE FRONT VIEW 2 7 14 3 13 2 1E 1C 11 1B 6 10 11 1G 4 17 ...

Page 59: ... 27x x1 6B DN2145 Assembly Recovery Unit Tall prior to 0001 8072 was 801 810 91x x1 RB 6A 6C DN35 Assembly Recovery Unit with Anti Pilfer Kit 801 817 42x x1 7 Deflector Bottle Drop Plastic Wedge 801 811 07x x1 8 DN2145 Door Stiffener Angle Recovery Unit prior to 079 8019 622 070 05x x3 9 DN2145 Magnet Recovery Unit prior to 079 8019 801 518 40x x1 10 Gasket Seal 902 100 32x x1 11A Spring Delivery ...

Page 60: ...60 CABINET DETAIL 14 3 9 12 3 1 2 7 8 8B 7 10 11 11 13 5 6 ...

Page 61: ...was 627 070 09x x3 627 070 29x x3 Right Tray Mounting Bracket Domestic DN5593 was 627 070 13x x3 627 070 35x x3 Right Tray Mounting Bracket Domestic DN5594 3594 627 070 26x x3 Right Tray Mounting Bracket Domestic 20 oz DN2145 622 070 03x x3 Right Tray Mounting Bracket Export DN2145 622 050 34x x3 Right Tray Mounting Bracket Mexico 600 ml DN2145 4 shelf 622 050 37x x3 4 DN55 35 Security Angle Hinge...

Page 62: ...62 LIGHTING EVAPORATOR FAN 21 4 2 1 13 12 3 7 7 13 12 9 11 10 14 14 6B 6A 6C Non Energy Star Energy Star ...

Page 63: ...9W Energy Star New EBM 5 Blade Metal 647 052 10x x3 Evaporator Fan Assembly 120V 60Hz 9W Energy Star ECM Original 7 Blade Plastic 627 052 40x x3 Evaporator Fan Assembly 120V 60Hz 9W Non Energy Star was W362 622 041 10x x3 Evaporator Fan Assembly 230V 50Hz 9W was W287 622 041 00x x3 Evaporator Fan Assembly 220V 50Hz 9W 622 043 00x x3 8 Evaporator Fan Motor EBM 5 Blade Metal 120V 60Hz Energy Star 80...

Page 64: ...64 SERVICE DOOR 1 1 5 6 7 8 6F 6J 3 6A 7 ...

Page 65: ...A Assembly Coin Return Lever 800 502 98x x1 5B Coin Return Lever Limiter 801 305 22x x1 6 T Handle Assembly 801 518 06x x1 6A Nut 20 Hex 801 518 02x x1 6B Washer 1 2 Int Tooth Lock 801 518 03x x1 6C 90 Degree Locking Cam 801 518 04x x1 6D Pawl 801 518 05x x1 6E E Ring 31 30 was 801 507 34x x1 901 503 07x x1 6F Lock Body Flush Mount 801 507 98x x1 6G Hex Washer 29 34 901 503 08x x1 6H Cross Pin T H...

Page 66: ...66 SERVICE DOOR 2 15 6 5 4 1 2 6 17 20 8 19 21 9 11 12 4 14 18 ...

Page 67: ...491 011 16x x3 13 Coin Return Door Flap prior to 0041 8019BX 622 050 14x x3 14 Keypad Cable Clamp Kit not shown D114 15 Validator Filler Plate All Dixie Narco built doors 360 050 72x x3 Validator Filler Plate All ECC built doors F283 16 Gasket Validator Filler Plate 902 001 11x x1 17 Coin Insert Label Service Door Bezel Domestic 803 902 72x x1 Coin Insert Label Service Door Bezel Large Export 803 ...

Page 68: ...68 SERVICE DOOR 3 12 17 2 20 7 5 13 19 14 15 11 4 10 9 8 ...

Page 69: ...800 202 55x x1 8 Latch Pawl 3 Point Lock 801 518 05x x1 9 Latch Rod 3 Point Lock 627 050 04x x3 10 Protective Strip Plastic 2 piece 801 810 07x x1 11 Keypad Cable Clamp D588 Keypad Cable Clamp Kit D114 12 Service Menu Label DN Energy Star 803 876 27x x1 Service Menu Label DN Non Energy Star 803 853 26x x1 13 Hopper and Coin Chute 801 806 58x x1 14 Coin Chute Front 801 806 59x x1 15 Cash Box 432 05...

Page 70: ...70 TALL GATE TRAY DETAIL 1 8 9 8 13 15 15 14A 14C 14B 18 16 14B 12 ...

Page 71: ...only 801 701 58x x1 Same Product Pusher Spring Old hook end 901 701 08x x1 Same 10 Tray Wire Formed Domestic 9 Column DN55 801 401 98x x1 801 401 89x x1 Tray Wire Formed Domestic 8 Column DN55 801 401 96x x1 Same Tray Wire Formed Domestic 6 Column DN35 801 402 21x x1 Same 11 Stiffener Side Shelf 622 070 04x x3 Same 12 Washer Retainer 125 ID was W398 800 701 71x x1 Same 13 Washer Solenoid Mounting ...

Page 72: ...cer B 90 70 801 812 81x x1 7 Spacer 340 210 777 was 801 813 53x x1 801 817 39x x1 8 Spacer 340 590 801 813 71x x1 9 Spacer 155 530 was 801 813 78x x1 801 821 67x x1 10 Spacer 155 405 was 801 813 76x x1 801 817 38x x1 11 Spacer Rail Assembly metal was 622 053 10x x3 801 815 36x x1 12 Product Pusher Rail 801 811 09x x1 13 Spacer Rail Plastic 801 815 32x x1 Part numbers descriptions are subject to ch...

Page 73: ...73 DOMESTIC AC DISTRIBUTION BOX 110 VAC Non Energy Star shown 4 7 12 1 3 2 6 9 11 13 14 25 5 8 10 20 ...

Page 74: ...ole Cover AC Dist Box for Temp Control Relocation prior to 0086 8018 622 060 08x x3 13 Temperature Control Label 803 847 08x x1 14 Temperature Control Clip 800 902 63x x1 15 Harness AC Power Choke Input 804 920 56x x1 16 Harness AC Distribution Box Power 804 920 48x x1 Harness AC Distribution Box Power 804 913 72x x1 17 Harness Choke Output 804 920 49x x1 18 Harness MDB Interior Power T8 Electroni...

Page 75: ...75 EXPORT AC DISTRIBUTION BOX 220 VAC 4 ...

Page 76: ... 250 V 5x20 mm Sloblo 804 914 24x x1 11B Fuse 1 Amp 250 V 5x20 mm Sloblo 804 914 23x x1 11C Fuse 1 25 Amp 250 V 5x20 mm Sloblo 804 919 56x x1 12 Power Inlet Plug 804 913 62x x1 13A Thermostat Harness 068 8018 to 0016 8095 was 804 915 05x x1 804 912 91x x1 13B Dual Thermostat Harness 0016 8095 and higher was 804 914 39x x1 804 925 92x x1 14A Dual Temp Control Bracket 0016 8095 and higher 622 060 13...

Page 77: ...77 REFRIGERATION UNIT DN 55 35 FIN TUBE CONDENSER 19 11 10 13 18 9 1 22 15 13 16 6 5 2 8 17 ...

Page 78: ...z 88 108MFD Export 802 502 28x x1 7 Start Capacitor End Cap Bottom Hole 802 501 18x x1 8 Bracket Capacitor Assembly 802 501 87x x1 9A Drain Pan Condensate Domestic 801 812 61x x1 9B Drain Pan Condensate Export 801 813 55x x1 10A Assembly Condenser Fan 16W 110V 10 Domestic 626 040 70x x3 10B Assembly Condenser Fan 16W 220V 10 Export 626 041 40x x3 11A Condenser Fan Motor 16W 110V Domestic 804 501 1...

Page 79: ...79 REFRIGERATION UNIT TECUMSEH DN 5500 DN 5400 DN 2145 ROLL UP CONDENSER ...

Page 80: ...acitor 250 V 50 Hz 88 108MFD 802 502 28x x1 5 Evaporator was W353 802 600 63x x1 6 Condenser Roll Up was 802 600 62x x1 obsolete 7 Overload 110V Tecumseh D608 1 Overload 220V Tecumseh D608 2 Overload T1 115V Aspera MST 16 AFN 3001 802 502 23x x1 Overload T1 220V Aspera MRP 20APK 34 802 502 26x x1 8 Refrigeration Kit 115V 60Hz 609 044 20x x4 no longer available RB 635 040 00x x4 Refrigeration Kit 2...

Page 81: ...Display 14 Segment Character 804 912 79x x1 Same 5 Transformer was 804 913 73x x1 804 915 54x x1 Same 6 Fuse AC Distribution Box 10 Amp SloBlow 32V W659 Same 7 Fuse AC Distribution Box 2 Amp 250 Volt SloBlow W658 Same 8 Battery 3 Volt Lithium CR2032 804 920 45x x1 Same 9A Lighted Vend Sensor Kit 627 022 10x x4 Same 9B Lighted Vend Sensor 804 924 07x x1 Same 9C Directional Disc 2 per order needed 8...

Page 82: ...82 HARNESSES 1 2 3 7 4A 6 4B 24 22 5A 5B 5C 9 10A ...

Page 83: ...27 010 02x x3 10C Harness DEX 15 See Item 9 11 Harness Energy Star Evaporator Fan 804 922 37x x1 Harness Energy Star Evaporator Fan Choke Extension 804 922 77x x1 12 Harness AC Power Choke Input 804 920 56x x1 13 Harness AC Box Power Distribution 804 920 48x x1 14 Harness Jumper AC Refrigeration 804 913 79x x1 15 Harness Choke Output 804 920 49x x1 16 Harness Interior Power T8 Electronic 0304 8225...

Page 84: ...abinet Pepsi Blue Cap Bottle 803 864 68x x1 Same 19 Decal Top Glass Door Domestic Export 803 851 89x x1 803 868 65x x1 Decal Top Glass Door Enjoy D621 Same 20 Decal Bottom Glass Door Pepsi 803 851 94x x1 803 868 66x x1 Decal Bottom Glass Door D618 Same 21 Decal Top Service Door Pepsi White Cap Bottle 803 851 93x x1 Same Decal Top Service Door Thirsty D622 Same 22 Decal Bottom Service Door Domestic...

Page 85: ...85 SCREWS NUTS ...

Page 86: ... Pan 8 32 x 3 4 was 900 201 22x x1 900 201 91x x1 A21 Screw Phil Pan Shoulder 8 18 x 1 2 was 900 301 98x x1 800 305 06x x1 A22 Screw Phil Pan 8 18x1 2 was 900 301 84x x1 800 304 31x x1 A23 Shoulder Screw 1 2 Long 900 500 26x x1 A24 Screw Hex Head 900 201 13x x1 A25 Screw Tap 1 4 20x1 Hex Type F was 900 301 73x x1 800 304 26x x1 A26 Screw Phil Pan 8 18x3 4 was 800 303 15x x1 800 304 76x x1 A27 Scre...

Page 87: ...87 WASHERS BOLTS MISC HARDWARE ...

Page 88: ...2 was 900 201 45x x1 800 202 45x x1 E5 Carriage Bolt 1 4 20 x 3 8 was 900 201 54x x1 800 202 46x x1 E6 Carriage Bolt 1 4 20 x 3 4 was 900 201 56x x1 800 202 47x x1 E7 Carriage Bolt 1 4 20x5 8 was 900 303 12x x1 obsolete E8 Carriage Bolt 5 16x18x1 1 4 Top Hinge drop in was 900 201 85x x1 800 202 54x x1 E9 Carriage Bolt 1 4 20x5 8 was 800 303 19x x1 800 304 08x x1 E10 Carriage Bolt 20x1 2 red was 90...

Page 89: ...1x x1 I7 Clamp Nylon 1 2 Heyco 3328 900 901 80x x1 I8 Hand Tie 5 5 901 901 06x x1 I9 Wire Tie 7 1 2 901 902 01x x1 10 Wire Ties 4 901 901 00x x1 11 Clamp Nylon 3 4 Heyco 3382BL 901 900 55x x1 12 Cable Tie 5 5 901 902 83x x1 13 Canoe Clip 254 090 301 00 0108 900 902 14x x1 Part numbers descriptions are subject to change with out notice NA Not applicable TBD To be determined RB Replaced by ...

Reviews: