1) Only Use On Flat Surface:
The NOMAD should only be used on a flat surface or at a maximum angle of 20
degrees off level. DO NOT operate this unit on its side or at angles greater than 20 degrees or permanent damage to
the compressor will occur.
2) Provide Adequate Ventilation and Avoid External Heat Sources:
In order to achieve the best
possible performance from the NOMAD we recommend 4" clearance around air vents. External heat sources such as
direct sunlight, gas stoves or other heat generating appliances should be avoided.
TEMP CONTROLLER QUICK START GUIDE
•
Do not set the temperature below 0°C/32°F or you risk freezing the beverage you are dispensing.
1.
Press the Power Button to turn on the unit.
2.
Press and release the “SET” button on the temperature
controller to enter into the settings menu.
3.
Press “SET” again to display the value of SEt; this is the
target temperature setting.
4.
Press the “UP/DOWN” arrows to adjust the value of
the target temperature.
5.
Press the button or wait 30 seconds, and the
setting will be saved, and the controller will return to
the home screen.
Adjusting the Differential
The Differential setting is how far the temperature is
allowed to rise before the compressor turns on to cool
the unit back to your programmed target temperature.
The default Differential setting is 2°C, but you can adjust
it if desired. To adjust the Differential setting:
1.
Press and release the “SET” button on the temperature
controller to enter into the settings menu.
2.
Press the “UP/DOWN” arrows till the display reads
diF for the Differential setting.
3.
Press “SET” again to display the value of diF.
4.
Press the “UP/DOWN” arrows to adjust the value of
the differential setting.
5.
Press the button or wait 30 seconds, and the
setting will be saved, and the controller will return to
the home screen.
For more detailed instructions, download the controller manual from our website.
Before attaching the NOMAD to your keg first screw your taps onto the two shanks on the front of the NOMAD and
tighten the shank collar using a 7 in 1 Facet Tap Wrench/Spanner Tool.
After tightening your taps onto the shanks, you can then plumb your kegs in to the NOMAD. On the back of the
NOMAD you will find two 8mm push in bulkhead fittings. Simply push 8mm OD EVABarrier tubing from your liquid
ball lock disconnect or keg coupler into the bulkhead fitting. Then attach the ball lock disconnect or keg coupler onto
your liquid keg post or spear respectively.
Ensure that the EVABarrier hose is cut straight and cleanly with a Stanley knife or 2 in 1 tube cutter (DUO200).
Then firmly push the EVABarrier hose into the opening of the bulkhead. Make sure that the hose is pushed in to its
full depth. Then check for a good connection by gently pulling bank on the hose. If the hose comes out of the push in
fitting, reinsert ensuring the hosing is pushed far enough into the fitting.
To remove EVABarrier hose from the push in fitting, simultaneously push the collar in while pulling the EVABarrier
hose out of the push in fitting. Once the hose is removed cut the burred end off with a 2 in 1 tube cutter or box knife
INSTALLATION REQUIREMENTS
DISPENSING
2