2.
Select “Cancel of Regeneration Disable” and press EN-
TER switch, and the regeneration disable is canceled.
If 3 or more soot accumulation gradations (3) light up, the
regeneration may be started automatically.
REMARK
• When canceling the regeneration disable, release the ac-
celerator pedal, set the gear shift lever in NEUTRAL posi-
tion (N), set the parking brake switch to “PARKING” posi-
tion, then cancel the regeneration disable.
• The regeneration disable setting is also canceled by turn-
ing the starting switch to OFF position to stop the engine.
Komatsu Closed Crankcase Ventilation (KCCV)
KCCV is a device to clean the gas discharged from the engine
crankcase with the filter element and return it to the engine air
intake system.
NOTICE
• The KCCV filter element needs to be replaced every
2000 hours.
• If the engine is operated without KCCV filter element
or if a filter element other than the Komatsu genuine
element is used, the engine sucks oil and foreign ma-
terial which can cause a failure.
Komatsu recommends using Komatsu genuine KCCV
filter element.
• The filter element cannot be cleaned.
Never reuse the filter element since it can cause a per-
formance decrement of engine, and it result in a failure
even if it is cleaned.
KOMTRAX Plus
k
k
WARNING
• Never disassemble, repair, modify, or move the KOMATRAX Plus, wireless communication terminal,
antenna, or cables. This may cause failure or fire on the wireless equipment or the machine itself.
• Near the blasting jobsite, there may be a danger of unexpected explosion due to use of the wireless
equipment and resulting serious personal injury or death.
If you have to operate the machine within 12 m from the remote-controlled blasting device, the pow-
er supply cable of the wireless communication device must be disconnected in advance.
The KOMTRAX Plus is a vehicle management system.
If the wireless communication terminal is installed to the machine, it can remotely manage the machines equip-
ped with the KOMTRAX Plus device through satellite communication or portable radio communication.
The machine information such as the machine maintenance, maintenance management, operating situation
management, and machine location management is gathered from the inside network of the machine. It can be
useful for you to perform the machine management by yourself. Your Komatsu distributor uses the above ma-
chine information for supply of service to the customers, improvement of our products and service, etc.
The type of information which is sent from the machine may vary depending on the machine. For the radio sta-
tion establishment of KOMTRAX Plus, consult your Komatsu distributor.
POWER SUPPLY FOR KOMTRAX Plus
• When a wireless communication terminal is installed to the machine, even if the starting switch key is in
OFF position, KOMTRAX Plus system consumes a small amount of electric power.
EXPLANATION OF COMPONENTS
OPERATION
3-136
Содержание HD465-8
Страница 2: ......
Страница 19: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 3 ...
Страница 20: ...SAFETY LABELS SAFETY 2 4 ...
Страница 53: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1 ...
Страница 319: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 ...
Страница 392: ......
Страница 393: ...SPECIFICATIONS 5 1 ...
Страница 397: ...ATTACHMENTS AND OP TIONS Before reading this chapter read and understand the SAFETY 6 1 ...
Страница 403: ...REPLACEMENT PARTS 7 1 ...
Страница 419: ......
Страница 420: ...HD465 8 HD605 8 Dumptruck Form No EENAM03550 2017 KOMATSU All Rights Reserved Printed in Belgium 02 2017 ...