Problem
Main causes
Remedy
Lamp does not glow brightly even
when the engine runs at high speed
•Defective wiring
•Defective adjustment of fan belt
tension
(•Check,repair loose terminals,
disconnections)
•Adjust alternator belt tension For
details, see EVERY 250
HOURS SERVICE
Lamp flickers while engine is run-
ning
Charge lamp does not go out even
when engine is running
•Defective alternator
•Defective wiring
(•Replace)
(•Check, repair)
Abnormal noise is generated from
alternator
•Defective alternator
(•Replace)
Starting motor does not turn when
starting switch is turned to ON
•Defective wiring
•Insufficient battery charge
•Safety switch out of adjust
(•Check, repair)
•Charge
(•Adjust safety switch)
Pinion of starting motor keeps going
in and out
•Insufficient battery charge
•Charge
Starting motor turns engine slug-
gishly
•Insufficient battery charge
•Defective starting motor
•Charge
(•Replace)
Starting motor disengages before
engine starts
•Defective wiring
•Insufficient battery charge
(•Check, repair)
•Charge
Automatic pre-heating is not actu-
ated
•Defective wiring
•Defective heater relay
•Defective engine controller
(•Check, repair)
(•Replace)
(•Check, replace)
Pre-heating pilot lamp does not light
up (When the engine coolant tem-
perature is below -5°C (23°F))
•Defective wiring
•Defective heater relay
(•Check, repair)
(•Replace)
Oil pressure caution lamp does not
light up when engine is stopped
(starting switch in ON position)
•Defective caution lamp
•Defective caution lamp switch
•Defective wiring
(•Replace)
(•Replace)
(•Check, repair)
Charge lamp does not light up when
engine is stopped (starting switch in
ON position)
•Defective charge lamp
•Defective wiring
(•Replace)
(•Check, repair)
Outside of electrical heater in not
worm when touched by hand
•Defective wiring
•Disconnection in electrical intake air
heater
•Defective operation of heater relay
(•Check, repair)
(•Replace)
(•Check, repair heater relay)
Air conditioner does not work prop-
erly
•Blown fuse
•Insufficient battery charge
•Defective air conditioner switch
•Defective blower switch
•Defective compressor
(•Check, repair)
•Charge
(•Replace air conditioner switch)
(•Replace blower switch)
(•Replace)
HSS charge pressure caution lamp
does not light up when starting
switch is turned ON
•Defective caution lamp
•Defective wiring
•Defective charge pressure sensor
(•Replace)
(•Check, repair)
(•Replace)
Содержание 76243
Страница 2: ......
Страница 3: ...FOREWORD 11 ...
Страница 5: ...FOREWORD FOREWORD 1 3 q Machine equipped without cab Back pocket of operator s seat ...
Страница 16: ...NECESSARY INFORMATION FOREWORD 1 14 ...
Страница 17: ...FOREWORD NECESSARY INFORMATION 1 15 ...
Страница 24: ...CONTENTS 1 22 ...
Страница 28: ...SAFETY LABELS SAFETY 2 4 SAFETY LABELS 2 POSITIONS OF SAFETY PICTOGRAMS 2 ...
Страница 211: ...MAINTENANCE 14 WARNING Please read and make sure that you understand the safety volume before reading this section ...
Страница 289: ...SPECIFICATIONS 15 ...
Страница 294: ...HEADREST HANDLING ATTACHMENTS OPTIONS 6 4 HEADREST HANDLING 6 Use the headrest fully pushed in to the lowest position ...
Страница 297: ...INDEX 17 ...
Страница 298: ...INDEX 7 2 ...
Страница 301: ...COLOPHON 18 ...
Страница 302: ...COLOPHON 8 2 D155AX 5 GALEO BULLDOZER Form No EEAM023402 2005 KOMATSU All Rights Reserved Printed in Belgium 09 05 ...