Page 8
The selection of the torque value is carried out by entering the digit cell by cell.
26) Torq max
–
Maximum Torque:
The minimum torque and maximum torque options allow the user
to set the acceptable torque range for the single application. When the reached torque is within this range,
“
Screw OK
” will be displayed on the status bar and the green led will light up.
If the reached torque is
outside this range,
“error minimum torque” or “error maximum torque”
will be displayed. You can set the
torque range from
‘
Torq Min+0.01
Nm’
to 55 Nm at intervals of 0.01 Nm.
The maximum torque option allows to set the highest value of the torque range. When Calibration is OFF
the maximum torque value automatically sets on 55 Nm.
The selection of the torque value is carried out by entering the digit cell by cell.
- - - - - M E N U - - P R : 1 - - - - -
2 7 ) I n s .
b a r c o d e
2 8 ) S e r i a l
P R T :
o f f
2 9 ) F u n c
T & A :
o f f
27) Ins. barcode:
to scan a barcode and recall the desired program. To be used in combination with option
4. of the Sequence Menu.
28) Serial PRT: Serial print
:
from OFF to 5.
When OFF, no print.
If it is set up to 5, this value identifies the number of line feeds between a string and another.
THE FOLLOWING MENU IS AVAILABLE ON T&A VERSION ONLY
- - - - - M E N U - - P R : 1 - - - - -
2 9 ) F u n c
T & A :
o f f
3 0 ) S t a r t i n g
T o r : - - -
3 1 ) A n g .
m i n :
- - - -
29) Func T&A
–
T&A function mode:
You can activate the Torque & Angle function. Set OFF when
you
don’t need
this function. When you set ON you can choose among six working conditions (see T&A
specific instructions).
30) Starting Tor
–
Starting torque:
If T&A option is set on Tor mode (See T&A paragraph), you can
set the torque threshold the angle starts to be read from. When T&A is set on angle mode (see T&A
paragraph), you can set the torque threshold the angle starts to be carried out from.
31) Ang. min
–
Minimum angle:
Minimum angle threshold. You can set it when T&A is set on Tor, T/in
or T/lv (see T&A specific instructions). The minimum angle the operator can set is 5°.
- - - - - M E N U - - P R : 1 - - - - -
3 1 ) A n g .
m i n :
- - - -
3 2 ) A n g .
m a x :
- - - -
Содержание EDU 2AE/TOP/NT
Страница 17: ...Page 17 I O CONNECTIONS...