Info USB: press OK and see the loaded program.
You can see the loaded program only if you have saved the program in your USB drive as named as
SETxx.KOL.
L o a d e d
p r o g r a m :
S E T 2 3 . K OL
TORQUE CALIBRATION
The torque calibration function allows to view the torque value in Nm or in.lbs or kgf.cm directly on the
display of the control unit.
IMPORTANT: You need a torque tester to proceed, either with static transducer (model minik or K)
or with rotary transducer (model minik-e).
EXAMPLE: You have an application where you need 1.5 Nm and you would like to see, after each screw,
the torque value on the display of your EDU2AE/TOP (as you know all information you see on the display
can be printed out through the serial port thus helping you to keep trace of
all fastening data). Let’s say you
are using a PLUTO6 screwdriver. Test the PLUTO6 on mini k5 torque tester and you find that you get
1.5Nm with the following parameters: Torque 25%, speed 920 RPM, SOFT Joint.
CALIBRATION PROCESS:
1. Select Calibration at point 23 of the menu and press OK.
2. The following screen will appear on the display:
- - - - - - - - M E N U - - - - - - - -
2 3 ) C a l i b r a t i o n
O N
3. Press OK to confirm. If you choose OFF, calibration will be interrupted and no torque value will be
displayed. You choose ON, calibration will continue and the following screen will be displayed:
4. Set the first torque level at 20% percentage by pressing
.
- - - - - - - - S T E P - - 1 - - - - -
E n t e r
t h e
p e r c e n t a g e
M I N