Kollmorgen - December 2011
307
MMC Smart Drive Hardware Manual
-
460V MMC SMART DRIVE DC BUS SHARING
Appendix B - 460V MMC Smart Drive DC Bus
Sharing
B.1
Introduction
This section discusses DC bus sharing among 2 or more 460V Smart Drives.
DC bus sharing accomplishes 4 things:
•
It pools the capacitance of all of the drives.
•
It lowers electricity cost.
•
It allows multiple dries to share one shunt resistor.
•
It allows the shunt energy to be shared among multiple shunt resistors.
Pooling the capacitance increases the Joule energy absorption capability to the sum
of the drives connected (
). This lowers energy cost slightly
because energy that can be absorbed is not wasted in the shunt resistors. In some
applications, this can eliminate the need for a shunt resistor altogether.
Many applications will have one drive motoring while the other is regenerating. This
energy is transferred from one drive to the other through the DC bus rather than being
dissipated in a shunt. This saves energy cost.
If it is desired to share one shunt resistor instead of using one per drive, the energy
flows through the DC bus to the drive controlling the shunt resistor. Its internal circuitry
will turn the shunt on when the bus voltage reaches an upper limit.
If it is desired to distribute the shunt load among multiple drives, each having a smaller
resistor, then
it is important to interconnect the “Shunt On” signals for all drives
sharing the DC bus
. This ensures that all of the shunt resistors will properly share the
load. If this connection is not made, it is likely that only one shunt resistor will dissipate
all of the shunt power, overheating it.
B.2
DC Bus Sharing with AC Power to All Drives
When sharing DC power among several drives with AC power supplying all of the
drives (
), all drives must be the same size (for example, all drives must be
MMC-SD-4.0-460). When two drives are connected to a shared DC bus in this
manner, the combined energy absorption of all drives is available.
3% line reactors are required for all sizes using this configuration to ensure rectifier
balance. However, shunt resistors are optional (see below). Refer to Chapter 4 in this
manual for information related to fusing, line reactors and shunts. Refer to Chapter 6
for connector information.
When more than one shunt is used with the MMC Smart Drives, it is important to tie
the “Shunt On” circuits together so that all shunts get turned on at the same time. For
example, in
, if the shunt connected to Drive 1 turns on, the “Shunt On”
signal will turn on the shunt for Drive 2. The second shunt resistor is optional as long
as the “Shunt On” signal is connected as shown. The “Shunt On” signal acts as both
an input and an output for each Drive.
Содержание Digital MMC Control
Страница 2: ......
Страница 10: ...8 Kollmorgen Decamber 2011 MMC Smart Drive Hardware Manual TABLE OF CONTENTS...
Страница 14: ...12 Kollmorgen December 2011 MMC Smart Drive Hardware Manual INTRODUCTION TO THE MMC SMART DRIVE...
Страница 128: ...126 Kollmorgen December 2011 MMC Smart Drive Hardware Manual 230V 1 3 PHASE MMC SMART DRIVE...
Страница 214: ...212 Kollmorgen December 2011 MMC Smart Drive Hardware Manual 460V 3 PHASE MMC SMART DRIVE...
Страница 246: ...244 Kollmorgen December 2011 MMC Smart Drive Hardware Manual MOTOR CABLES CONNECTORS...
Страница 296: ...294 Kollmorgen December 2011 MMC Smart Drive Hardware Manual DRIVE RESIDENT DIGITAL MMC CONTROL...
Страница 297: ...Kollmorgen December 2011 295 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY 13 Declarations of Conformity...
Страница 298: ...296 Kollmorgen December 2011 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY...
Страница 299: ...Kollmorgen December 2011 297 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY...
Страница 300: ...298 Kollmorgen December 2011 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY...
Страница 301: ...Kollmorgen December 2011 299 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY...
Страница 302: ...300 Kollmorgen December 2011 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY...
Страница 320: ...MMC Smart Drive Hardware Manual INDEX 318 Kollmorgen March 2011...
Страница 322: ...320 Kollmorgen December 2011 MMC Smart Drive Hardware Manual SALES AND SERVICE...