AKD-N Installation | 6 Technical description and data
6.13.2.3 Switch-off behavior using HW Enable input on AKD-C (uncontrolled stop)
This is a category 0 stop according to IEC 60204. The hardware enable input disables the
AKD-N power stage immediately.
If velocity drops below threshold
CS.VTHRESH
or timeout occurs the motor holding brake is
applied. Set parameter MOTOR.BRAKEIMM to 1 with vertical axes, to apply the motor hold-
ing brake immediately after Hardware Disable.
32
Kollmorgen | December 2014
Содержание AKD-N00307
Страница 6: ...This page intentionally left blank AKD N Installation Table of Contents 6 Kollmorgen December 2014...
Страница 52: ...AKD N Installation 8 Electrical Installation 8 5 3 Connection diagram AKD Nzzz07 DB 52 Kollmorgen December 2014...
Страница 69: ...This page intentionally left blank AKD N Installation 10 Index Kollmorgen December 2014 69...