KOLDWAVE 3AK (AIRMASTER)

3AK3012 AIRMASTER PRODUCT DATA AND SPECIFICATIONS

ELECTRICAL DATA***

Voltage/Phase/Hertz****

208-230/1/60

Amperage

13.0

Fuse Size (Amps)

20.0

Watts

2603

Inrush Current (Amps)

89.26

COMPRESSOR

Horsepower

2.0

Watts

2090

RLA

9.6

LRA

62.5

RPM

3450

Refrigerant - 22 (oz.)

68

BLOWER (EVAPORATOR)

Speed

High

Medium

Low

Amps

1.9

1.4

1.3

Watts

323

250

230

RPM

1135

960

840

CFM @ 0.0" H

2

O E.S.P.

835

695

605

with Grille
CFM @ 0.0" H

2

O E.S.P.

710

630

575

with Snozzles
CFM @ 0.5" H

2

O E.S.P.

465

395

360

with Snozzles
CFM @ 0.0" H

2

O E.S.P.

760

660

590

with 10" Diameter Duct
CFM @ 0.5" H

2

O E.S.P.

505

410

370

with 10" Diameter duct

COOLING CAPACITY (BTU/HR) & EER

Evaporator Fan Speed

High

Medium

Low

Conditions

Total

Sensible

EER*

Total

Sensible

EER*

Total

Sensible

EER*

67°F DB/57°F WB (54% RH)

21,450

15,400

10.25

20,800

14,400

10.25

20,300

13,600

10.10

72°F DB/60°F WB (50% RH)

22,450

16,550

10.30

21,750

15,450

10.35

21,150

14,500

10.20

75°F DB/62°F WB (48% RH)

23,000

17,150

10.35

22,200

15,750

10.35

21,500

14,750

10.20

80°F DB/67°F WB (52% RH)

24,300

15,800

10.50

 23,550

15,050

10.55

22,600

14,100

10.25

95°F DB/71°F WB (30% RH)

25,950

21,000

10.00

25,100

20,000

10.00

24,250

18,750

  9.75

95°F DB/75°F WB (40% RH)

26,550

17,950

10.20

25,800

17,000

10.25

25,050

16,250

10.05

95°F DB/83°F WB (61% RH)

27,150

 11,250

10.40

26,500

11,000

10.45

25,750

10,650

10.20

104°F DB/80°F WB (36% RH)

26,900

17,650

  9.50

26,100

16,900

  9.50

25,400

16,100

  9.35

115°F DB/96°F WB (50% RH)**

29,950

11,150

  9.50

29,350

10,700

  9.55

28,700

10,300

  9.40

Time delay fuses and circuit breakers are recommended.

***

* EER determined with condenser discharge air ducted into

another area on high fan speed.

**

** Maximum operating condition.

*

*** Electrical ratings per U.L Standard 484 at 95°F DB/75° WB

on high speed.

**** 220/50/1 available - consult factory

BLOWER (CONDENSER)

Speed

High

Low

Amps

2.3

1.6

Watts

420

290

RPM

1070

740

CFM @ 0.0 E.S.P.

1110

753

CFM @ 0.25 E.S.P.

955

690

CONDENSATE PUMP (OPTIONAL)

Motor HP

0.013

Lift (Ft. of H

2

O)

11.0

Amps

0.26

Watts

50

EVAPORATOR

Number of Rows

3

Coil Face Area (Ft.

2

)

2.36

CONDENSER

Number of Rows

3

Coil Face Area (Ft.

2

)

5.25

EVAPORATOR AIR FILTER SIZE (INCHES)

Width

16.5

Height

17.25

Thickness

0.5

CONDENSER AIR FILTER SIZE (INCHES) 2/UNIT

Width

17.375

Height

20.0

Thickness

0.5

UNIT DIMENSIONS (INCHES)

(A) Height with Casters

52.25

(B) Height without Casters

48.5

(C) Width

22.25

(D) Depth

33.625

NET UNIT WEIGHT (LBS.)

303

SHIPPING WEIGHT (LBS.)

365

C

D

B

A

Содержание AIRMASTER 3AK

Страница 1: ...ire refrigeration system electrical components condenser and evaporator housed in one attractively designed two tone enamel finish metal cabinet NOMENCLATURE 3 A K 30 1 2 5 Series 50 Hz Air Cooled 208...

Страница 2: ...500 15 500 9 65 95 F DB 75 F WB 40 RH 21 350 14 100 10 25 21 100 13 350 10 25 20 200 12 750 10 00 95 F DB 83 F WB 61 RH 21 900 8 800 10 45 21 700 8 550 10 45 20 850 8 450 10 25 104 F DB 80 F WB 36 RH...

Страница 3: ...30 RH 25 950 21 000 10 00 25 100 20 000 10 00 24 250 18 750 9 75 95 F DB 75 F WB 40 RH 26 550 17 950 10 20 25 800 17 000 10 25 25 050 16 250 10 05 95 F DB 83 F WB 61 RH 27 150 11 250 10 40 26 500 11 0...

Страница 4: ...to virtually any location SERVICEABILITY The Koldwave Airmaster has removable panels to provide full service accessibility The interior is divided into three accessible sections upper front lower fron...

Страница 5: ...selector rocker switch located on the control panel has three functions 1 To provide fan mode only operation when depressed to the left 2 To turn the unit off when set in the center position 3 To act...

Страница 6: ...l box located in the lower back section of the unit The electrical box encases the compressor s run capacitor a transformer the compressor contactor a freeze control a condenser fan speed selector and...

Страница 7: ...sate water from unit 1 With condensate tank and water level detection system which comes standard on unit See detailed drawing and discussion below 2 With optional condensate pump kit shown on page 16...

Страница 8: ...mpressor until temperature levels are safe again The approximate thermostat cut out cut in are 290 140 F HIGH PRESSURE CUT OUT The Koldwave Airmaster incorporates within the refrigeration system a man...

Страница 9: ...9 KOLDWAVE 3AK AIRMASTER ACCESSORIES...

Страница 10: ...ting into the false ceiling plus a duct collar to attach duct to the unit Installation of the flexible duct can be achieved in the following manner 1 Slip one end of the duct over the lay in ceiling p...

Страница 11: ...D 2411 Plenum installed with additional optional accessory kits on plenum inlet and unit discharge Installation Procedure 1 Remove seventeen 10 24 x 1 2 long phillips head screws securing left hand si...

Страница 12: ...12 KOLDWAVE 3AK AIRMASTER...

Страница 13: ...ive equipment production processes and personnel This can be accomplished by optional dual 6 diameter snozzles 23 long compressed and 31 long extended flexible air duct The snozzles are secured to a p...

Страница 14: ...ir duct part 040 C 0025 can be used with this kit for remote spot cooling The duct is secured to a 16 gauge light grey painted galvanneal mounting plate by a clamp part SA019 A 0067 The duct assembly...

Страница 15: ...Single 10 Diameter Evaporator Discharge Duct On application where one large cold air supply duct is desired a mounting plate with a single 10 diameter mounting flange is available which mounts just a...

Страница 16: ...MBLY 1 Disconnect unit power source 2 Open front lower hinged door 3 Pull out plastic drain hose form inside of tank and remove tank from hinged tray Do not drain hose from evaporator drain pan 4 Moun...

Страница 17: ...g provides convenient economical and energy efficient air conditioning in areas where cooling the entire environment is impractical The cool air is directed only where it is aimed or needed without wa...

Страница 18: ...e air conditioner spot cooler for any shipping damage Air conditioners are throughly inspected at the factory and carefully packed If any damage is evident file a claim with the delivering carrier imm...

Страница 19: ...l to determine electrical power and installation requirements to allow the spot cooler to perform at its maximum efficiency Refer to general description wiring diagrams and photographs to get an under...

Страница 20: ...evaporator coil 3 Ice on evaporator coil 4 Obstructed intake 5 Wrong speed on evaporator fan motor 6 Evaporator fan motor miswired 1 Refrigerant leak 2 Plugged cap tubes or strainer 1 Check external...

Отзывы: