background image

Owner’s Manual

6CC10BEA2AA00

20

21

Wiring Diagram

Figure 26 - Circuit Wiring Diagram

POWER

BLOWER

COOL

DEHUMID

SPOT/COOL

ALARM

CURRENT 

TEMP/HUMID

TARGET 

TEMP/HUMID

MCCB

Power

1P AC 115V-60Hz

1P AC 208-230V, 50/60Hz

E

L

N

T (AC) S

CP

PU

HT

EXT

COM

EMC

L

H

TH1
TH1

OUT_TEMP

SENSOR

SEN1

SEN2

SEN3

TH2
TH2

TH3
TH3

IN_TEMP

SENSOR

ICE_TEMP

SENSOR

MC 1

OCR 1

C

EVA'

MOTOR

C

C

R
S

COMP'

FND

PS (HP)

COM

COM

EXT

FU

FT

CO

COM

DRAIN

PUMP

IN_HUMIDITY

SENSOR

IR/FU

TH4

TH4

L - 2

N - 2

COM

L

H

COM

L

H

COM

CP

N-1

L-1

COM CO

COM

Power Remote

Control (Option)

EXT

COM

(FUSE)

(FUSE)

HIGH

PRESSURE

SWITCH

L
N

C

COND'

MOTOR

Spark

Arrestor

COM

HP

FU

ALARM

NO COM NC

WIFI & RF

ON/OFF

SWITCH

(Option)

LOW

PRESSURE

SWITCH

(Option)

IR/FT

LP

LP

WMC-2500 CD3.31

Содержание 6CC10BEA2AA00

Страница 1: ...eas where cooling of the entire area is not practical or possible A dedicated spot cooling thermostat controls the unit in this application This Unit can also be used in smaller areas for room cooling...

Страница 2: ...ndle Cool air duct assembly Caster ASSEMBLY SERVER RACK 9 Component Parts Universal adjust Rack Assembly Rack Diffuser ASSEMBLY MOUNTED HANG 10 Condenser Intake Air Duct Flange Eva Intake Air Duct Fla...

Страница 3: ...t to your environmental needs These accessories Portable Kit Server Rack Kit Hanging Kit Stack Kit are sold separately to allow you to customize the 6CC10BEA2AA00 to your specific needs Shipping list...

Страница 4: ...r Duct Diame ter In mm Maximum Duct Length ft m 6CC10BEA2AA00 320 220 9 1 6 2 4 76 2mm 6 150 10 3 Safety Devices Compressor overload protector Anti freezing thermister Automatic restart Power interrup...

Страница 5: ...d for a minimum of 15A 18 DO NOT unplug the unit by pulling on the electrical cord Keep electrical cord away from heat sources and always completely unroll the cord to avoid overheating If the power c...

Страница 6: ...is unit occupies just 12U of valuable rack space Server Rack kit includes server rack assy shelf universal adjust mount feet and rack diffuser MOUNTED HANG It can be used to mounted type where your ne...

Страница 7: ...ews enclosed inside of accessory box with cord holder to install the cord holder in the unit as shown in Figure 4 Display Control Panel Cool Air Outlet Evaporator Filter Condenser Filter Power cord Ho...

Страница 8: ...the casters on the base panel of unit 3 Use screws enclosed inside of accessory box with caster to install in the unit as shown in Figure 8 The unit is upright position only Leave unit in an up right...

Страница 9: ...ment 1 Assemble the rack assembly parts 1set 6ea to fit in server rack 2 Use screws to install the rack assembly in server rack as shown in Figure 11 3 Place the unit on the rack assembly RACK ASSEMBL...

Страница 10: ...ioner 4 Use screw enclosed inside of box with condenser flange to install the flange as shown in Figure 15 1 Remove Eva intake air duct flange 1 pcs from carton 2 Slide up filter on the front of the u...

Страница 11: ...anging kit to install as shown in Figure 17 5 Lift and mounted the unit Removing the power supply cord and permanently connection the unit should be per formed only by a qualified electrician 6CC10BEA...

Страница 12: ...e panel of unit 3 Install on the unit as shown in Figure 19 The unit is upright position only Leave unit in an up right position for at least 3 hours before first use 1 Take out the stacking bracket 1...

Страница 13: ...OTE Make sure the AC outlet is free of dirt dust oil water or any other foreign material The unit is equipped with an approved NEMA plug configuration 6CC10BEA2AA00 5 15P The appropriate outlet must b...

Страница 14: ...essed COOL DEHUMID pressing will make Spot cooling available 4 DEHUMID BUTTON Room Cool Spot Cool will be converted to Dehumidifying function after pressing Dehumid button 5 SET TEMP HUMID BUTTONS Tem...

Страница 15: ...t Temperature and Humidity set by pressing button respectively 9 ALARM Alarm indicator lights blinks and indicates abnormal system operation If Alarm occurs compressor stops System operation stops whe...

Страница 16: ...se the filter grill 6 To clean the condenser filter lift up on the rear filter from the middle bar slightly and then angle the filter outwards from the bottom and remove 7 Use the same cleaning proced...

Страница 17: ...on the unit NOTE For effective cooling clean the filter at least every 2 weeks Figure 24 Removing condenser Filters Figure 25 Removing evap orator Filters For your convenience record the complete mode...

Страница 18: ...C CODES See Table 1 The alarm light is activated if abnormal operation occurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan...

Страница 19: ...nsor value TH1 Outlet temperature sensor has a loose or broken connection Contact a qualified service agent Abnormal tem perature sensor value TH2 Inlet temperature sensor has a loose or broken connec...

Страница 20: ...1 OUT_TEMP SENSOR SEN1 SEN2 SEN3 TH2 TH2 TH3 TH3 IN_TEMP SENSOR ICE_TEMP SENSOR MC 1 OCR 1 C EVA MOTOR C C R S COMP FND PS HP COM COM EXT FU FT CO COM DRAIN PUMP IN_HUMIDITY SENSOR IR FU TH4 TH4 L 2 N...

Страница 21: ...led if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before turning the...

Страница 22: ...lve the problem call Koldwave Portable Air Conditioner Technical Support at 214 638 6010 Please have the following information available BEFORE calling the Technical Support Department a Your name and...

Страница 23: ...Owner s Manual 6CC10BEA2AA00 23 For Koldwave warranty please visit http koldwave com html literature asp...

Страница 24: ...Owner s Manual 6CC10BEA2AA00 24 KOLDWAVE 125 North Elm St Westfield Ma 01085 USA PH 252 753 1921 Fax 252 753 1953 www koldwave com Printed in August 2019...

Отзывы: