background image

SC200 Installation& Operation Manual

 

3-16

 

 

 

 

 

 

 

 

 

20 

 

 

 

CONTROL BOX ASSY 

 

 

 

 

 

 

 

 

 

 

 

Description 

 

 

 

102103701 

RELAY-PLUG-IN DPDT 115VAC 

 

 

 

102100701 

SOCKET - IDEC #SH2B-02 

 

 

 

510110601 

ROCKER SWITCH SPST QUICK CONNECT 

 

 

 

102145903 

CONTROL PCB     SC200 

 

 

 

102145701 

TEMP PROBE 55" PCB 1.8 

 

 

 

510127701 

SC HARVEST ASSIST SWITCH PUSH 

BUTTON 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SC200 Series

Страница 1: ...anual Kold Draft International LLC 1525 East Lake Road Erie PA 16511 1088 U S A Phone 800 840 9577 Fax 800 548 9392 www kold draft com This manual is updated periodically Visit http www kold draft com...

Страница 2: ...RAFT INTERNATIONAL LLC Unauthorized reproduction of this manual is freely permitted for all purposes except for monetary gain It is not guaranteed that this service manual is up to date technically co...

Страница 3: ...ion Requirements 4 Plumbing 5 Electrical 6 Ice Cube Information 6 Section 3 Operation Initial Start Procedure 7 Ice Machine Restart 7 Controls and Adjustments 8 Sequence of Operation 9 Description of...

Страница 4: ...arrange replacement or repair Read the entire manual before installing operating or servicing the machine To ensure optimal efficiency and productivity follow these installation instructions exactly A...

Страница 5: ...15 volt 60 hz 1ph 2 wire plus ground 4 208 230 volt 60 hz 1ph 2 wire plus ground 7 220 240 volt 50 hz 1ph 2 wire plus ground Modification Code 0 No Modifications Series 2 200 Series Model Family SC Se...

Страница 6: ...ent failure NOTE Each Kold Draft ice machine has successfully completed a quality assurance test and has been factory inspected before shipping Unpacking Unpacking a KOLD DRAFT machine can be done by...

Страница 7: ...quired around the top and sides but must be provided in back for plumbing and electrical connections and in front for free flow of air in and out of the condensing unit compartment Do not install air...

Страница 8: ...for greater operating efficiency Supply water temperatures higher than the recommended maximum will cause reduced capacities The water supply must be potable not laden with sediment and have free chl...

Страница 9: ...ed adjacent to each ice maker are recommended and may be required by local codes These components must be supplied by the installer Electrical service must fall within the voltage tolerances listed be...

Страница 10: ...into the bin 5 The machine will begin to make ice 6 When ice is available test the bin probe adjustment by holding ice against it Adjust the controller if required Code 90 indicates ice bin full a co...

Страница 11: ...ubes without a dimple will reduce ice machine capacity and may cause damage to the water plate and operating mechanism Bin Probe This probe will sense contact with the ice when the bin is full and tur...

Страница 12: ...Status Status Status Status Bin Level Probe Warm Not Full Warm Not Full Warm Not Full Warm Not Full Warm Not Full Ice Clean Switch Ice Ice Ice Ice Ice Harvest Switch Run Run Run Run Run Evaporator Te...

Страница 13: ...rator continues to warm until the ice falls out onto the water plate and into the ice bin When the evaporator reaches a pre set temperature indicating that all the ice has dropped out the defrost valv...

Страница 14: ...Shutdown High Pressure All models are provided with a high pressure cutoff which interrupts power to the compressor and to the condenser fan motor if so equipped when the high side pressure rises to t...

Страница 15: ...zing solution containing 0 5 ounce 15 mL 5 1 4 sodium hypochlorite household bleach or equivalent and 1 gallon 3 8 liter warm clean water 5 Pour the sanitizing solution into the sump Leaving the Ice C...

Страница 16: ...ic power supply Disconnect water and drain lines Remove and empty the water sump Open water valve and dump valve and blow compressed air through all lines Remove and drain the water plate assembly Rea...

Страница 17: ...SC200 Installation Operation Manual 3 16 14 Wiring Diagram...

Страница 18: ...igeration system is overcharged Remove refrigerant and recharge the system to specifications Compressor thermal protector is open because of low voltage condition Allow thermal protector to reset Meas...

Страница 19: ...st Cold potable water supply Make sure water supply temperature is within the acceptable range Water valve will not close Potable water level continues to rise after the float is fully up No voltage m...

Страница 20: ...fective Float switch OK but no voltage measured at water valve coil at fill cycle Check for line voltage at controller output to water valve Controller could be defective Actuator motor turns wrong wa...

Страница 21: ...101 SC200 EVAPORATOR KIT C CUBE Quantity per Uom Description 1 0 EA SC EVAPORATOR ASSEMBLY C CUBE 1 0 EA SC TXV BULB CLIP 1 0 PC SCREW 8 32 X 5 8 PH PAN HD SS 4 0 PC 10 32 THREADED STANDOFF 7 16 OD x...

Страница 22: ...L BOX ASSY Description 102103701 1 RELAY PLUG IN DPDT 115VAC 102100701 1 SOCKET IDEC SH2B 02 510110601 1 ROCKER SWITCH SPST QUICK CONNECT 102145903 1 CONTROL PCB SC200 102145701 1 TEMP PROBE 55 PCB 1...

Страница 23: ...PH PAN SS 4 0000 PC LOCKNUT 8 32 SS W NYLON INSERT 1 0000 EA SC FAN MOTOR 115V 230V 1550 RPM CCW CW 1 0000 EA SC FAN BLADE PLASTIC 200 MM DIA 28 DEGREE PITCH 1 0000 EA SC FAN BLADE WALL RING PLASTIC...

Страница 24: ...505116401 1 SC OPERATOR LEFT SIDE 15 505116501 1 SC OPERATOR RIGHT SIDE 16 505116601 2 SC LINK BUSHING 17 505116701 2 SC WATER PLATE BUSHING 18 505116801 2 SC200 HD200 SHAFT BEARING 19 505116902 2 SC...

Страница 25: ...RELAY 102151603 OVERLOAD 301184201 WATER PLATE DEFLECTOR 102148601 ACTUATOR MOTOR W MAGNETIC SWITCHES CPACITOR 301126101 ELECTRICAL INLET BOX COVER 516103301 WATER PUMP 505107601 BIN COVER 5550144001...

Страница 26: ...SC200 Installation Operation Manual 3 16 22...

Отзывы: