Problems and Solutions 

 

PROBLEM 

POSSIBLE CAUSE 

SOLUTION 

Water plate will not close 

after defrost. 

Actuator motor output shaft is turning but 

front cam is not turning.  

Connection between actuator motor 

shaft and right side operator broken.  

Check set screw, tighten or replace. 

Actuator motor will not run.  No voltage 

measured at actuator motor.   

Inspect operation of plate up and plate 

down switches.  Adjust or replace if 

defective. 

  

  

  

Defrost cycle ends before 

all ice is out of the 

evaporator 

Evaporator grids are distorted, slowing 

the fall of the ice from the evaporator. 

Carefully straighten grids or replace 

evaporator if the damage is severe. 

Excessive scale build-up in evaporator 

cells 

Clean and de-scale ice machine  

  

  

  

Ice remains attached to 

the water plate surface at 

the end of defrost. 

Ice frozen into the water plate surface.  

Thick web between ice cubes. 

Adjust web thickness to specifications.   

Over-freezing 

Increase the temperature set point that 

initiates harvest. 

Cold potable water supply. 

Make sure water supply temperature is 

within the acceptable range. 

  

  

  

Water valve will not close. 

Potable water level 

continues to rise after the 

float is fully up. 

No voltage measured at water valve coil.  

Water valve remains open because of 

water supply problem.   

The water supply pressure must be a 

minimum of 5 PSI (34 kPa) dynamic at 

the water valve.  Be sure that the 

supply line is of adequate size.  This is 

especially important for liquid cooled 

models where the potable water and 

condenser coolant water are supplied 

by the same water line.  Check for 

restrictions in the water supply line 

including clogged filters.  Check the 

water valve strainer and clean it if 

needed.    

No voltage measured at water valve coil.  

Water valve remains open because of 

dirty or defective water valve.   

Disassemble and clean water valve if 

needed.  Make sure the bleed holes in 

the valve diaphragm are open.  

Replace water valve if defective. 

Line voltage measured at water valve 

coil. 

Test for proper water float switch 

operation. Reed switch could be 

defective. 

Water level float switch OK, but line 

voltage measured at water valve coil. 

Check controller for output to water 

valve.  Controller could be defective 

Содержание SC200 Series

Страница 1: ...anual Kold Draft International LLC 1525 East Lake Road Erie PA 16511 1088 U S A Phone 800 840 9577 Fax 800 548 9392 www kold draft com This manual is updated periodically Visit http www kold draft com...

Страница 2: ...RAFT INTERNATIONAL LLC Unauthorized reproduction of this manual is freely permitted for all purposes except for monetary gain It is not guaranteed that this service manual is up to date technically co...

Страница 3: ...ion Requirements 4 Plumbing 5 Electrical 6 Ice Cube Information 6 Section 3 Operation Initial Start Procedure 7 Ice Machine Restart 7 Controls and Adjustments 8 Sequence of Operation 9 Description of...

Страница 4: ...arrange replacement or repair Read the entire manual before installing operating or servicing the machine To ensure optimal efficiency and productivity follow these installation instructions exactly A...

Страница 5: ...15 volt 60 hz 1ph 2 wire plus ground 4 208 230 volt 60 hz 1ph 2 wire plus ground 7 220 240 volt 50 hz 1ph 2 wire plus ground Modification Code 0 No Modifications Series 2 200 Series Model Family SC Se...

Страница 6: ...ent failure NOTE Each Kold Draft ice machine has successfully completed a quality assurance test and has been factory inspected before shipping Unpacking Unpacking a KOLD DRAFT machine can be done by...

Страница 7: ...quired around the top and sides but must be provided in back for plumbing and electrical connections and in front for free flow of air in and out of the condensing unit compartment Do not install air...

Страница 8: ...for greater operating efficiency Supply water temperatures higher than the recommended maximum will cause reduced capacities The water supply must be potable not laden with sediment and have free chl...

Страница 9: ...ed adjacent to each ice maker are recommended and may be required by local codes These components must be supplied by the installer Electrical service must fall within the voltage tolerances listed be...

Страница 10: ...into the bin 5 The machine will begin to make ice 6 When ice is available test the bin probe adjustment by holding ice against it Adjust the controller if required Code 90 indicates ice bin full a co...

Страница 11: ...ubes without a dimple will reduce ice machine capacity and may cause damage to the water plate and operating mechanism Bin Probe This probe will sense contact with the ice when the bin is full and tur...

Страница 12: ...Status Status Status Status Bin Level Probe Warm Not Full Warm Not Full Warm Not Full Warm Not Full Warm Not Full Ice Clean Switch Ice Ice Ice Ice Ice Harvest Switch Run Run Run Run Run Evaporator Te...

Страница 13: ...rator continues to warm until the ice falls out onto the water plate and into the ice bin When the evaporator reaches a pre set temperature indicating that all the ice has dropped out the defrost valv...

Страница 14: ...Shutdown High Pressure All models are provided with a high pressure cutoff which interrupts power to the compressor and to the condenser fan motor if so equipped when the high side pressure rises to t...

Страница 15: ...zing solution containing 0 5 ounce 15 mL 5 1 4 sodium hypochlorite household bleach or equivalent and 1 gallon 3 8 liter warm clean water 5 Pour the sanitizing solution into the sump Leaving the Ice C...

Страница 16: ...ic power supply Disconnect water and drain lines Remove and empty the water sump Open water valve and dump valve and blow compressed air through all lines Remove and drain the water plate assembly Rea...

Страница 17: ...SC200 Installation Operation Manual 3 16 14 Wiring Diagram...

Страница 18: ...igeration system is overcharged Remove refrigerant and recharge the system to specifications Compressor thermal protector is open because of low voltage condition Allow thermal protector to reset Meas...

Страница 19: ...st Cold potable water supply Make sure water supply temperature is within the acceptable range Water valve will not close Potable water level continues to rise after the float is fully up No voltage m...

Страница 20: ...fective Float switch OK but no voltage measured at water valve coil at fill cycle Check for line voltage at controller output to water valve Controller could be defective Actuator motor turns wrong wa...

Страница 21: ...101 SC200 EVAPORATOR KIT C CUBE Quantity per Uom Description 1 0 EA SC EVAPORATOR ASSEMBLY C CUBE 1 0 EA SC TXV BULB CLIP 1 0 PC SCREW 8 32 X 5 8 PH PAN HD SS 4 0 PC 10 32 THREADED STANDOFF 7 16 OD x...

Страница 22: ...L BOX ASSY Description 102103701 1 RELAY PLUG IN DPDT 115VAC 102100701 1 SOCKET IDEC SH2B 02 510110601 1 ROCKER SWITCH SPST QUICK CONNECT 102145903 1 CONTROL PCB SC200 102145701 1 TEMP PROBE 55 PCB 1...

Страница 23: ...PH PAN SS 4 0000 PC LOCKNUT 8 32 SS W NYLON INSERT 1 0000 EA SC FAN MOTOR 115V 230V 1550 RPM CCW CW 1 0000 EA SC FAN BLADE PLASTIC 200 MM DIA 28 DEGREE PITCH 1 0000 EA SC FAN BLADE WALL RING PLASTIC...

Страница 24: ...505116401 1 SC OPERATOR LEFT SIDE 15 505116501 1 SC OPERATOR RIGHT SIDE 16 505116601 2 SC LINK BUSHING 17 505116701 2 SC WATER PLATE BUSHING 18 505116801 2 SC200 HD200 SHAFT BEARING 19 505116902 2 SC...

Страница 25: ...RELAY 102151603 OVERLOAD 301184201 WATER PLATE DEFLECTOR 102148601 ACTUATOR MOTOR W MAGNETIC SWITCHES CPACITOR 301126101 ELECTRICAL INLET BOX COVER 516103301 WATER PUMP 505107601 BIN COVER 5550144001...

Страница 26: ...SC200 Installation Operation Manual 3 16 22...

Отзывы: