17
(3) After setting the skin in place, adjust the volume of air in the amnion while palpating the
tension of the amnion.
[REFERENCE]
As the volume of air in the amnion becomes larger, the situation where palpation is more
difficult can be simulated. Using a smaller volume of air simulates the situation where
palpation is easier. Adjust to suit the situation.
[CAUTION]
When excessive amount of air is injected into the amnion, the amnion may burst. Inject air
while checking the tension of the amnion by touching the abdomen of the model.
(4) When finishing adjusting the amount of air in the amnion, close the two-way stopcock in
order to avoid an air leak from the amnion.
*If this operation is not performed, the air in the amnion will deflate over time.
The setting before use is completed.
*Attach the skin to the manikin when practicing nipple massage or breast care.
- 16 -
(4) When finishing adjusting the amount of air in the amnion, close the two-way stopcock
in
order to avoid an air leak from the amnion.
*If this operation is not performed, the air in the amnion will deflate over time.
The setting before use is completed.
*Attach the skin to the manikin when practicing nipple massage or breast care.