16
- 15 -
※ 羊膜インジケーターの使用方法は「P.16 8-5,羊膜インジケーターの使い方」を参照し
てください。
(2)表皮乳頭部の裏面と本体乳頭部の面を合わせてから表皮をセットします。
※表皮止め用のマジックテープは肩に2カ所、本体側面に6カ所、下腹部に2カ所あります。
腹部になるべくしわが出来ないように、表皮を手で伸ばしながらマジックテープで固定し
てください。
(3) After setting the skin in place, adjust the volume of air in the amnion while palpating the
tension of the amnion.
[REFERENCE]
As the volume of air in the amnion becomes larger, the situation where palpation is more
difficult can be simulated. Using a smaller volume of air simulates the situation where
palpation is easier. Adjust to suit the situation.
[CAUTION]
When excessive amount of air is injected into the amnion, the amnion may burst. Inject air
while checking the tension of the amnion by touching the abdomen of the model.
表皮
表皮乳頭の裏面
本体乳頭部
(2) Place the skin on the manikin only after aligning the underside of the nipples on the skin
with the nipples on the surface of the manikin.
*For fixing the skin in place, two hook and loop fasteners are located on the shoulders, six on
the sides, and two on the lower part of the abdomen.
While smoothing down the skin with the hand to eliminate wrinkles on the abdomen,
secure it with the hook and loop fasteners.
Skin
Underside of the nipple
on the skin
Nipple