background image

1

Handling and Safety Precautions

These precautions should be strictly observed in order to ensure safe, 

long-term use of the product.

The following precautions should be observed particularly strictly:

1.  The model is made with a special material to simulate the texture of human skin. We recommend 

that it be handled carefully, in the same manner as an actual person. The model may become 
damaged by pulling at it with excessive force or if it suffers a strong impact, for example if 
dropped.

2.  The material of the umbilical cord contained in this Umbilical Cord Kit has a distinct odor. This 

odor is not harmful to the human body and does not indicate poor quality. The distinct odor 
fades with time. There may also be a smell of baby powder remaining on the product, as baby 
powder is applied to the model during the manufacturing process.

3.  Wear disposable gloves when practicing with the model.
4.  Apply a moderate amount of lubricant (glycerin) to the fetal model and placenta model before 

use.

5.  Please do not use oily lubricant (baby oil, olive oil etc.), alcohol lubricant, and lubricant containing 

organic solvent. These may cause breakage of the model.

6.  In caring for the model, do not use rubbing alcohol, thinners, or benzin or other organic solvents 

on the model, as doing so may cause damage.

7.  Do not use oil-based inks, pencil, chalk, or paints on the model, as they may cause permanent 

staining.

8.  Placing objects directly on top of the model or placing it on uneven surfaces may change the 

shape of the model.

9.  If the surface becomes sticky or after washing the model following use, apply baby powder all 

over the model to reduce friction.

10. The umbilical cord contained in this Umbilical Cord Kit may lose its shape after a long time. 

Check the shape of the model about 3 years after purchase. If it is deformed to the extent that 
correct functioning is affected, consider replacing it.

11. Air bubbles or impressions in the umbilical cord contained in this Umbilical Cord Kit that may 

remain from the manufacturing process do not affect the strength of the material, as the 
material used is strongly tear-resistant.

Содержание LM-101D

Страница 1: ...Kit Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4 14 Koraku Bunkyo ku Tokyo 112 0004 JAPAN URL http...

Страница 2: ...model and placenta model before use 5 Please do not use oily lubricant baby oil olive oil etc alcohol lubricant and lubricant containing organic solvent These may cause breakage of the model 6 In cari...

Страница 3: ...nt may cause its shape to change Exposure to direct sunlight or ultraviolet rays may also alter its shape or color Store the model at a temperature of 0 50 C in a place where it will not be exposed to...

Страница 4: ...odels 3 1 Attaching the fetal model LM 0633 and placenta model LM 0634 3 2 Attaching the fetal model LM 114A and placenta model LM 114B 3 3 Attaching the fetal model LM 114A and placenta model LM 0634...

Страница 5: ...tire sequence of steps from delivering the fetus to tying and cutting the umbilical cord and delivering the placenta 2 The umbilical cord contained in this Umbilical Cord Kit has a tear resistant text...

Страница 6: ...placenta model LM 0634 1 Take the umbilical cord contained in this Umbilical Cord Kit and roll down the end that has a hole in it until a string loop appears 2 Roll down the end of the umbilical cord...

Страница 7: ...it is not covered by the end of the umbilical cord of the placenta model they will come apart during delivery Make sure the parts are not lubricated when attaching them together It will be difficult t...

Страница 8: ...l cord contained in this Umbilical Cord Kit If the end of the umbilical cord contained in this Umbilical Cord Kit is not covered by the umbilical cord connector they may come apart 6 Assembly is now c...

Страница 9: ...d of the umbilical cord connector with a hook attached until the hook is visible and then attach the hook to the umbilical ring of the umbilical cord contained in this Umbilical Cord Kit After attachi...

Страница 10: ...emove the umbilical cover from the fetal model and then thread the outer part of the umbilical cord contained in this Umbilical Cord Kit through it 5 Clamp the umbilical cord contained in this Umbilic...

Страница 11: ...is a grove in the fetal model s umbilicus as shown in the gure below Make sure to t the umbilical cover s ange into the groove 7 Assembly is now complete To re attach the umbilical cord contained in...

Страница 12: ...as rolled back so it covers the end of the umbilical cord contained in this kit If the end of the umbilical cord contained in this Umbilical Cord Kit is not covered by the end of the placenta model s...

Страница 13: ...sure the parts are not lubricated when attaching them together If the parts are lubricated with glycerin etc during this step the umbilical cord contained in this Umbilical Cord Kit will become slippe...

Страница 14: ...ge into the groove 7 Assembly is now complete To re attach the umbilical cord contained in this Umbilical Cord Kit after it has been cut restart the procedure from step 4 Apply adequate glycerin to th...

Страница 15: ...Roll back the end of the umbilical cord connector with a hook attached until the hook is visible and then attach the hook to the umbilical ring of the umbilical cord contained in this Umbilical Cord K...

Страница 16: ...fter clamping them together unroll the end of the umbilical cord connector that was rolled back so it covers the end of the umbilical cord 4 Roll back the end of another umbilical cord connector with...

Страница 17: ...of the umbilical cord contained in this kit If the umbilical cord connector does not cover the end of the umbilical cord contained in this Umbilical Cord Kit the parts may separate 6 Assembly is now c...

Страница 18: ...e Total length Diameter Weight Umbilical cord Approx 12 cm Approx 1 4 cm Approx 16 g Umbilical cord connector Approx 4 cm Approx 1 6 cm Approx 7 g Quantity 1 1 1 Quantity 0 1 1 Quantity 1 1 1 Quantity...

Отзывы:

Похожие инструкции для LM-101D