background image

TT-1640 11/14

INSTALLATION INSTRUCTIONS

Original Issue Date:

11/14

Model:

125/150EOZDJ/EOZCJ and 100/125EFOZDJ/EFOZCJ

Market:

Marine

Subject:

Radiator Cooling and Dry Exhaust Kits

Introduction

Install this kit to convert a unit from keel cooling to
radiator cooling. When installing this kit, follow the
guidelines and observe the safety precautions.

Do not install these kits on units equipped with a heat
exchanger, a sound shield, or a Power Takeoff (PTO).

Model

Loose Kit Number

125EOZDJ/100EFOZDJ

150EOZDJ/125EFOZDJ

GM90678-KP1-WHT

125EOZCJ/100EFOZCJ

150EOZCJ/125EFOZCJ

GM90678-KP1-G49

Figure 1

Kit Selection (Standard Radiator)

Model

Loose Kit Number

125EOZDJ/100EFOZDJ

150EOZDJ/125EFOZDJ

GM90678-KP2-WHT

125EOZCJ/100EFOZCJ

150EOZCJ/125EFOZCJ

GM90678-KP2-G49

Figure 2

Kit Selection (Radiator with Protective

Coating)

Read the entire installation procedure and compare the

kit parts with the parts list at the end of this publication

before beginning installation. Perform the steps in the

order shown.

Safety Precautions

Observe the following safety precautions while installing

the kit.

Accidental starting.

Can cause severe injury or death.

Disconnect the battery cables before

working on the generator set.

Remove the negative (--) lead first

when disconnecting the battery.

Reconnect the negative (--) lead last

when reconnecting the battery.

WARNING

Disabling the generator set. Accidental starting can

cause severe injury or death.

Before working on the

generator set or equipment connected to the set, disable the

generator set as follows: (1) Press the generator set off/reset

button to shut down the generator set. (2) Disconnect the

power to the battery charger, if equipped. (3) Remove the

battery cables, negative (--) lead first. Reconnect the negative

(--) lead last when reconnecting the battery. Follow these

precautions to prevent the starting of the generator set by the

remote start/stop switch.

Hot coolant and steam.

Can cause severe injury or death.

Before removing the pressure cap,

stop the generator set and allow it to

cool. Then loosen the pressure cap

to relieve pressure.

WARNING

Allow the engine to cool. Release pressure from the

cooling system before removing the pressure cap. To

release pressure, cover the pressure cap with a thick

cloth and then slowly turn the cap counterclockwise to

the first stop. Remove the cap after pressure has been

completely released and the engine has cooled. Check

the coolant level at the tank if the generator set has a

coolant recovery tank.

Содержание TT-1640

Страница 1: ...th Disconnect the battery cables before working on the generator set Remove the negative lead first when disconnecting the battery Reconnect the negative lead last when reconnecting the battery WARNIN...

Страница 2: ...rd coolant recovery tank and dry exhaust elbow 2 1 Remove the belt guard belt guard brackets coolant recovery tank and bracket and hose that connects to the pressure cap See Figure 3 2 2 Remove the dr...

Страница 3: ...Remove and discard the existing belt 2 Belt guard bracket LH GM93388 WHT or G49 washer M125A 10 80 and screw M933 10025 60 3 Washer X 25 40 and screw M933 06020 60 4 Belt guard bracket GM90898 WHT or...

Страница 4: ...2 3 5 6 7 4 GM90678 C 8 Figure 9 Belt Guard Assembly 7 1 Assemble the belt guard as shown in Figure 9 7 2 Using the belt guard bracket assemblies attach the belt guard to the engine See Figure 9 and F...

Страница 5: ...923 06 80 9 5 Connect the upper radiator hose GM90937 to the radiator and engine port using two hose clamps X 426 2 to secure See Figure 11 for location Note Place hose clamps 6 mm 0 25 in from the ho...

Страница 6: ...3 10030 60 and 4 nuts M6923 10 80 per side See Figure 12 and Figure 13 10 3 Attach the right hand radiator support GM90787 to the radiator using 4 washers M125A 08 80 and 4 screws M933 08012 60 See Fi...

Страница 7: ...X 426 2 qty 2 13 Fan shroud brackets 343422 qty 2 washers X 25 75 qty 6 and screws M933 08016 60 qty 6 14 Radiator assembly GM90767 or GM90768 15 Cable tie X 468 1 16 Remove plug from top tank of rad...

Страница 8: ...ipe coupling X 216 23 16 Drain valve 278788 17 Belt guard top GM90779 18 Washers X 25 40 qty 6 and screws M933 06014 60 qty 6 19 Washers M125A 08 80 qty 2 and screws M933 08012 60 qty 2 20 Belt guard...

Страница 9: ...amage The block heater will fail if the energized heater element is not immersed in coolant Fill the cooling system before turning on the block heater Run the engine until it is warm and refill the ra...

Страница 10: ...in OD X 25 75 1 Connector hose X 380 5 1 Line flex X 386 90 4 Clamp hose 2 31 3 25 in X 426 2 1 Cable tie X 468 1 1 Connector hose X 582 39 6 Insert threaded X 6365 2 2 Clamp insulated 2 62 in X 672 3...

Страница 11: ...TT 1640 11 14 11 1 Coolant Level Sensor 1 See the full wiring diagram in the operation manual GM93792B A Figure 18 Wiring for Coolant Level Sensor Typical...

Страница 12: ...er Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone 65 6264 6422 Fax 65 6264 6455 Availability is subject to change without notice Kohler Co reserves the right to change the...