5. Secure the Shower Receptor
IMPORTANT!
If the shower receptor is not level, correct door alignment will be difficult to achieve.
Confirm the shower receptor is level. If required level the shower receptor.
Apply beads of foam adhesive on the ridges on the bottom of the shower receptor.
Reposition the shower receptor and press down firmly to ensure good adhesive contact.
IMPORTANT!
When using a drill to install the screws, make sure the drill does not contact the shower
receptor. It will damage the surface.
Locate and drill 3/16
″
clearance holes in the vertical center of the nailing flange, centered on each
stud.
Using screws, secure the receptor to the studs and bridging through the clearance holes.
Top View
Bottom View
Nailing
Flange
Foam
Adhesive
1100676-2-F