8
MaInTenanCe
general
this Product is precision engineered and should give continued safe and controlled
performance, provided:
1.
It is installed, commissioned, operated and maintained in accordance with
manufacturers recommendations.
2.
Periodic attention is given, when necessary, to maintain the product in good
functional order.
the Kohler Salute thermostatic mixer is designed for the minimum of maintenance
in normal use. If a malfunction occurs with the thermostatic cartridge then this will
necessitate a complete cartridge replacement.
note!
the cartridge contains no internally serviceable parts.
Lubricants
Silicone-only based lubricants can be used to assist in refitting.
Caution!
oil based or other lubricant types, may cause rapid deterioration of
seals.
Cleaning
Warning!
many household cleaners contain abrasive and chemical substances, and
should not be used for cleaning plated or plastic fittings. These finishes should be
cleaned using a mild washing up detergent or soap solution, rinsed and then wiped
dry with a soft cloth.
In-service Tests
the principle means for determining the continuing satisfactory performance of the
mixing vale is the in-service test.
Follow the procedure detailed in the flow diagram “In-service Test Procedure”.
Frequency of In-service Tests
Commercial (non-domestic installations)
check for correct blend setting every 6 months.
Follow the procedure detailed in the flow diagram “In-service Test Procedure”, every
months.