5
CoMMIssIonIng
Maximum Temperature setting
the maximum temperature of the thermostatic mixer is factory set to approximately
43°c. If adjustment is required, set the maximum temperature as follows:
note!
make sure that the hot water temperature is at least 0°c above the required
maximum showering temperature.
For type installations the maximum blend temperature is determined by the
application, refer to section:
‘Type 2 Valves - application’
.
1.
remove the Blanking cap and loosen the control Knob Grubscrew.
2.
turn on the thermostatic mixer to the maximum temperature (i.e. fully
anticlockwise) and allow the temperature to stabilise.
3.
Pull off the control Knob.
4.
unscrew the hub retaining Screw with a .5 mm hexagon Key (supplied).
note!
Do not remove the
hub.
5.
Insert the .5 mm hexagon Key into the centre of the Spindle and engage with
the recessed temperature adjusting Screw.
6.
rotate the hexagon Key until the required maximum temperature is obtained
at the discharge point. anticlockwise to increase the temperature, or clockwise
to decrease the temperature (
¼
turn = °c).
7.
once the desired maximum blend temperature has been achieved turn off the
thermostatic mixer by rotating the hub.
note!
Do not remove the
hub.
8.
Refit the Hub Retaining Screw.
9.
Refit the Control Knob, tighten the Grubscrew and refit the Blanking Cap.
Grubscrew
Blanking cap
control Knob
hub retaining
Screw
hub
HoT
CoLD
Spindle