background image

1154809-T01-B

IMPORTANT CONSUMER INFORMATION

Consumer Responsibilities

1. Do not attack the sensor.

2. Do not directly flush the sensor with water. The sensor is

an electronic instrument.

3. Do not let sunlight or other light source enter or be

reflected into Sensor Window.

4. Do not hang on the opposite wall any reflective items or

install light/electronic sensor such as toilet flushing sensor.

5. Do not make Sensor Window near strong ultraviolet or

electromagnetic field.

6. Keep the sensor window clean.

The sensor cover can be cleaned by soft rag with neutral
liquid detergent.
Do not use eradicator, abrasive powder or oil, acid or
alkali liquid detergent.
Do not spray air freshener, disinfectant or other kinds of
odious removing, cleaning organic liquid to the sensor
directly.

7. Urinal is designed for use with potable water. Avoid water

that includes a lot of contaminants or acid/alkali water and
impure water.

8. When AC power unit is connected to 220V AC power

supply, corresponding protective measures should be
taken.

9. Please confirm no water penetration at the connection

area of AC wire, and the connection area is not easy to
be affected by damp.

10. Don t connect power unit to AC power supply until the

sensor installation is finished.

11. The head AC power supply must be protected with

appropriate fuse.

12. Please confirm the AC power supply and water supply

should be shut off before maintaining the products with
AC power related.

13. All electrical connection must be compliance with related

regulation and codes.

14. All installation staff should be well familiar with

installation instruction.

'

1.

2.

3.

4.

(

)

5.

6.

7.

8.

220V

9.

10.

11.

12.

13.

14.

-13-

WARNING

WARNING: Risk of product damage.

Never spit phlegm and throw stub or

something else into the urinal.

Do not throw into the urinal what is easy to block it,
such as newspaper, paper pilch.
Do not bump the vitreous china with great force to
prevent it from damaging and leaking.
Do not use the product in the water below 0 C.

o

CAUTION:

Please do not use hard materials (like

scouring pad) to clean product surface, especially the
product logo.

0 C

o

Содержание PATIO ECO K-16321T-Y

Страница 1: ...the right to make changes in product characteristics packaging or availability at any time without notice These instructions contain important care cleaning and warranty information please leave inst...

Страница 2: ...ushing after used 2 AAA size alkaline batteries 16321T YC05 0 18 0 55MPa 0 5L 1 55 C 0 05 0 86MPa 70cm 50 70cm 2 5 220V 50 60Hz 16321T Y 2 7 AAA 2 30 30cm 2 SENSOR SPECIFICATIONS SENSOR SPECIFICATIONS...

Страница 3: ...e ceiling please chisel out a slot and layout bushing according to Fig and thread wire through the bushing One AC power unit can supply two sensors at most C Ceiling Slot Slot AC Power Unit Bushing In...

Страница 4: ...ad AC power supply must be protected with appropriate fuse e Please confirm the AC power supply and water supply should be shut off before maintaining the products with AC power related 2 2 a Keep the...

Страница 5: ...Pipe C C Install the inlet hose of valve assy Take out the bracket of valve assy Install the limited board 1 Tighten the tighten screw 2 The inserting depth postion is shown Connect the inlet pipe wi...

Страница 6: ...on is inserted the S trap way can be crutched by hard exterded via the gap in the bottom of the urinal to install it decently Then fix the urinal on the hook a Avoid the urinal fallen on the floor to...

Страница 7: ...AC power unit with control box assy with the same color wires 16321T Y 16321T YC05 3 A 2 7 16321T Y 16321T YC05 B Note B Press the two sides spring hooks of bracket of valve assy close to the center...

Страница 8: ...screw Push the limited board to the urinal withstanding the wall 4 and then tighten the tighten screw 5 a When installing the 16321T YC05 AC do not connect to power supply until finish installation b...

Страница 9: ...ng Distance During the first 10 minutes when powered on the system is in the phase of automatic regulation and no operation is required 10 Deodorizing Flushing The urinal will take a flush automatical...

Страница 10: ...30 Notice Used in places of low water pressure If the flushing amount is limited due to low water pressure you can set a long time washing with flushing control stick Operate as follows Ten minutes a...

Страница 11: ...brush and reinstall a Turn off the water supply before cleaning the filter also power off when used the AC power supply b Avoid damaging or losing the filter during cleaning Caution a b MAINTENANCE F...

Страница 12: ...small hole of valve core with thin steel wire 2 Wash the filter of valve core with a brush Replace batteries Please make following checks before repair Symptoms Probable causes Corrective actions If...

Страница 13: ...to 220V AC power supply corresponding protective measures should be taken 9 Please confirm no water penetration at the connection area of AC wire and the connection area is not easy to be affected by...