16

Advice to Users
Note! 

Read the 

Important Safety Information

 section first.

Warning! 

The spray plate holes must be kept clear. The spray plate should be regularly

removed and cleaned in descalent. Lack of regular spray plate cleaning will lead to
poor performance and cause early failure of the appliance. See the shower fittings
User Guide for more information.

1.

Electric showers work by taking in cold water and passing it over the heating
elements contained in the tank inside the shower.

2.

The showering temperature is adjusted by turning the temperature control knob,
which varies the flow of cold water across the elements. The slower the rate of
flow, the warmer the water, and vice versa. The holes in the spray plate of the
shower handset should always be kept clean to maintain a consistent flow and
stable shower temperatures.

3.

The appliance is designed to stabilise temperature changes caused by water
pressure fluctuations. These fluctuations can be caused by taps being turned on
or off, or toilets being flushed. Under such conditions, average shower temperatures
will be held within a 6°C range, provided that the minimum required pressure is
maintained.

4.

Seasonal changes in the temperature of the incoming cold water supply and/or
fluctuations in mains electrical voltage will effect the temperature of the water.
Adjust the temperature knob as necessary to compensate.

5.

The shower requires a minimum maintained/running pressure of 0.7 bar (70 kPa)
to operate. At pressures above 0.7 bar (70 kPa), the shower will minimise the
temperature fluctuations caused when other draw-off points are used. If the flow
rate drops below an acceptable level, the heating element inside the shower will
turn off, resulting in a cold shower.

6.

If the water temperature reaches an unsafe level, the thermal switch assembly
turns off the heating elements.  As the water temperature falls the elements will
be turned on.  The switch will cycle on/off/on if the flow rate is not increased and
the temperature of the shower reduced.

7.

Check the shower temperature before entering the shower. The previous user
may have selected a 

different

 temperature setting.

8.

When the shower is first turned on, or the temperature setting is changed, there
will be a slight delay before the water temperature changes.

OPERATION

Содержание Mira Zest

Страница 1: ...1 These instructions are to be left with the user Installation and User Guide ELECTRIC SHOWER MIRA ZEST...

Страница 2: ...st with low interest rates PRICE MATCH always get the best deals available Boilers Radiators Heating controls Pipes ittings Cylinders Fires Renewable energy Bathroom suites Kitchen sinks taps Showers...

Страница 3: ...tandards and Approvals 8 Flow Rate Graph 8 Installation Requirements 9 Plumbing 9 Electrical 11 Installation 12 Commissioning 14 Operation 16 Fault Diagnosis 18 Maintenance 22 Cleaning 22 Cleaning the...

Страница 4: ...enjoy the full potential of your new shower please take time to read this guide thoroughly and keep it handy for future reference Mira Zest electric showers have separate controls for power selection...

Страница 5: ...ers recommended outlet fittings should be used 8 If water leaks from the pressure relief valve maintenance will be required before the appliance can be safely used 9 There are no user serviceable comp...

Страница 6: ...with the requirements of UK Water Regulations Bye laws Scotland Building Regulations or any particular regulations and practices specified by the local water company or water undertakers The installat...

Страница 7: ...crews 1 x Mira Zest Electric Shower Documentation 1 x Installation User Guide 1 x Installation Template 1 x Guarantee Brochure Z Tick the appropriate boxes to familiarise yourself with the part names...

Страница 8: ...7 SPECIFICATIONS 205 mm 103 mm 53 mm 310 mm Dimensions Wiring Diagram...

Страница 9: ...e relevant directives for CE marking Flow Rate Graph 1 These curves are for the specified outputs at 240 V 2 All appliance heating elements have a manufacturing tolerance Flow rates may be above or be...

Страница 10: ...ed away from the appliance 4 The appliance is fitted with an inlet connector assembly that is designed to accept plumbing supplies from the top or bottom The water supply can be fed with 15 mm pipe or...

Страница 11: ...ale formation Appliance malfunction due to excessive limescale formation is not covered by the manufacturer s guarantee Your local water company will be able to advise on the hardness of water in your...

Страница 12: ...ble is not mechanically protected 2 5 mm2 if mechanically protected 3 The minimum cable size cross sectional area must conform to BS7671 4 To obtain full advantage of the power provided by this unit u...

Страница 13: ...points as shown on the template 3 Remove the installation template and drill the top two fixing holes Insert the supplied wall plugs Caution Do not drill into cables or pipes in the wall 4 Thoroughly...

Страница 14: ...e bottom fixing hole 14 Remove the shower from the wall Drill the bottom fixing hole and insert the supplied wall plug 15 Thoroughly flush the mains fed cold water supply pipe Caution The supply must...

Страница 15: ...hem reach the terminal block 22 Connect the conductors firmly into the terminal block Make sure that the bare cores of each conductor are securely trapped within each conductor clamp 23 If necessary f...

Страница 16: ...nob to the MEDIUM position The temperature of the water should rise slightly Allow a few seconds for the warm water to reach the handset this shows that the MEDIUM power setting is operating correctly...

Страница 17: ...verage shower temperatures will be held within a 6 C range provided that the minimum required pressure is maintained 4 Seasonal changes in the temperature of the incoming cold water supply and or fluc...

Страница 18: ...as necessary Turn the knob clockwise for hotter water and anticlockwise for cooler water Wait 10 15 seconds for the adjusted temperature to reach the handset Note It is normal for the flow rate to cha...

Страница 19: ...andset manual Remove and clean the handset sprayplate Refer to the Maintenance section of the handset manual If the fault persists contact the shower installer Contact your installer to replace the fl...

Страница 20: ...ntact the shower installer Contact installer to replace faulty parts Failure of pressure switch micro switch or thermal switch Turn the temperature knob anticlockwise to reduce the water temperature T...

Страница 21: ...rn off the heating element to reduce the water temperature Turn the temperature knob anticlockwise to reduce the water temperature DO NOT TAMPER with the thermal switch Turning the temperature knob do...

Страница 22: ...er ball is ejected Reset the relief valve assembly refer to Maintenance Relief Valve Setting If the fault persists contact Customer Services The water cannot be turned off Replace the flow regulator a...

Страница 23: ...ry use a kettle descalent in accordance with the manufacturer s instructions 6 Refit the components in reverse order Any maintenance must be carried out by a qualified tradesperson following the instr...

Страница 24: ...regulator assembly 4 Using your finger push the ball back into the tank Do not remove the O seal 5 Refit the components in reverse order 6 Replace the cover If the cover does not fit easily rotate the...

Страница 25: ...5 8 5 kW 439 79 Switch Assembly Rotary 439 81 Cover Assembly Zest 439 87 Terminal Block Assembly 439 88 Seal Pack components identified B 439 89 Screw Pack components identified C 439 90 Thermal Trip...

Страница 26: ...25 Spare Parts Diagram 439 87 439 95 439 81 439 90 439 99 439 91 439 92 A 439 79 439 77 A B B B B 406 27 439 75 C C C C...

Страница 27: ...26 NOTES...

Страница 28: ...27 NOTES...

Страница 29: ...28 1057732 W2 A Kohler Mira Limited January 2006 CUSTOMER SERVICE 7 5...