29
1383572-W2-A
If the malfunction has not been detailed in the fault finding table or it was not possible
to correct the malfunction, professional assistance may be required.
Symptom
Possible Cause
Possible Remedy
Shower fails to operate
Isolator switch in the off position
Switch on the electrical supply via the pull
cord or wall mounted switch
Fuse blown or MCB/RCD tripped,
indicating possible electrical fault
Renew the fuse or reset the MCB/RCD. If fault
persists, contact your installer
Low water flow.
No water flow.
Hose or shower head blocked. Filter
blocked or removed.
Remove and clean. Check hose and replace
if necessary. Refit all parts correctly.
Water supply isolating valve set too
low or turned off.
Fully open isolating valve.
Air in system.
Refer to cleaning / replacing the filter and air
purge section.
If this does not clear the air contact your
installer and refer to commissioning section.
Insufficient water pressure or water
flow for shower operation.
Gravity fed system, minimum pressure 0.8
kPa. (0.008 bar / 80mm head.)
Flow Valve faulty.
Contact your installer to replace.
Heater Tank excessively scaled.
Contact your installer to replace. Consult your
installer about fitting a water softener for hard
water areas.
Pump overheated or faulty.
Wait 30 minutes for pump to cool and reset
automatically. If fault persists, contact your
installer to replace.
Water pressure below minimum
required for shower operation.
Make sure shower isolating valve is fully
turned on. Check filter for blockage and clean.
Water flow stops and
motor tone increases.
Stored water is blocked or has
run out.
Turn shower off immediately!
Make sure there is a constant water supply
when shower is in use.
Air in system.
Refer to cleaning / replacing the filter and air
purge section.
If this does not clear the air contact your
installer and refer to commissioning section.
Water will not turn off.
Shower’s Flow Valve, Solenoid or
Start/Stop switch has failed.
Contact your installer to replace parts as
required.
Unable to select a cool
enough temperature.
Stored water temperature has
increased.
Turn the power control to eco and readjust
the temperature control.
Filter, Hose or shower head blocked.
Remove and clean. Check hose and replace
if necessary.
Temperature dial in incorrect
position.
Rotate temperature dial anti-clockwise until
desired temperature is reached.Switch the
power selector to Eco if required.
User Trouble Shooting