4 Operating faults
Please consult the table “Faults – Cause – Solution” for certain engine problems
with possible causes and corrective action.
Information
Engine errors are shown on the diagnosis and service tool as an error code for
diagnostic purposes.
The following table shows basic logical steps to diagnose the problem:
– Familiarize yourself with the engine and related systems.
– Investigate the problem carefully.
– Correlate the symptoms with your current knowledge of the engine and
systems.
– Diagnose the problem, starting with the most obvious assumptions.
– Carry out detailed analyses before taking the engine apart.
– Identify the causes and thoroughly perform any repair work.
After the repair:
– run the engine in accordance with the User Manual.
– Check that the causes have been eliminated.
– Cancel the fault.
4.1 Faults – Cause – Solution
Malfunction / error
Cause
Remedy
The starter does not turn over.
The main fuse has blown.
Replace the fuse.
The battery connections are loose or
corroded.
Clean and tighten the loose
connections.
The battery voltage is too low.
Charge or replace the battery.
The starter’s circuit is faulty or the
contacts are corroded.
Contact your nearest Kohler Co.
service representative. See the
Section "Service Assistance".
The starter is faulty.
Contact your nearest Kohler Co.
service representative. See the
Section "Service Assistance".
The starter turns over slowly.
The battery voltage is too low.
Charge or replace the battery.
The battery connections are loose or
corroded.
Clean and tighten the loose
connections.
The outside temperature is too low.
Take appropriate action for Winter
operation.
KD36V16 33521029701_1_1 en 2018-08-01
© 2018 by Kohler Co. All rights reserved.
35