Troubleshooting (cont.)
Symptom
Probable
Cause
Recommended Action
2.
Low flow.
A.
Supply
stop is not
fully open.
•
Remove the cover on the end
of the supply stop.
•
Turn the supply stop screw
counterclockwise until it is in
the fully open position.
•
Replace the cover.
B.
Supply
stop is not
allowing
enough
flow.
•
Remove the cover on end of
the supply stop.
•
While testing the flush, adjust
the supply stop screw
counterclockwise until
adequate flow is achieved.
•
Replace the cover.
C.
Supply
pressure is
low.
•
Check any filtration systems for
blockage.
•
Measure the incoming water
pressure. Minimum pressure
should be 20 psi (1 kPa).
3.
Constant
flow.
A.
Filter is
plugged.
•
Follow the directions of
″
Clean
the Screen/Replace the Piston
″
section in this guide.
B.
Diaphragm
seal is
dirty or
damaged.
•
Follow the directions of
″
Clean/Replace the
Diaphragm
″
section in this
guide.
•
NOTE:
Take care to replace the
diaphragm in its seat before
installing it into the valve body.
•
If the diaphragm is cut or torn,
order a new diaphragm
assembly.
C.
Solenoid is
not
working.
•
Order and install a new
solenoid assembly.
•
Follow the directions of
″
Remove the Solenoid
″
and
″
Install the Solenoid
″
sections
in this guide.
Kohler Co.
21
1108709-5-C
Содержание K-10673