4 — PROGRAM MENU PARAMETERS
pg. 27
Curtis Model 3150R – Oct. 2022
MISC MENU
The following table describes the parameters on the Misc menu.
MISC MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
HYD Controller Enable
0x6556:00
Off/On
0–1
32-bit
OEM Dealer
On
Specifies whether fault codes for the hydraulic
controller are displayed.
Speed Unit
0x6021:00
Enumerated
0–1
32-bit
OEM Dealer
KPH
Specifies the speedometer’s unit of measurement:
0 = KPH
1 = MPH
GUI Select
0x6709:02
Enumerated
0–4
32-bit
OEM Dealer
GUI-1
Specifies the user interface:
0 = GUI-1
1 = GUI-2
2 = GUI-3
3 = GUI-4
4 = GUI-5
Logo Select
0x6553:00
0–1
0–1
32-bit
OEM Dealer
0
Indicates whether a logo displays after the device
first powers up.
0 = No logo
1 = Curtis logo
LCD Heater Enable
0x6709:03
Off/On
0–1
32-bit
OEM Dealer
On
Indicates whether the LCD heater is disabled.
Note:
If the gauge is powered by the external 12V
supply of a Curtis motor controller, disable the LCD
heater. This is because of the controllers’ external
power supply limits.